Heat & Glo SL-750TRS-IPI-D Owner's Manual page 24

Hide thumbs Also See for SL-750TRS-IPI-D:
Table of Contents

Advertisement

V
1' MIN. (305mm)
2' MIN. (610mm)
3' MIN. (914mm)
4' MIN. (1.22m)
V+H=40' MAX. (12.4m)
H = 8' MAX. (2.4m)
Use DVP-Series
components only.
Figure 12. Venting with One 90° Elbow
Use SL D-Series
components only.
VENTING WITH ONE (1) 90
MODEL: SL-350TRS-C
V (MIN.)
H (MAX.)
90
o
Elbow on Top
2.5 FT (762mm)
1 FT (305mm)
3 FT (914mm)
2 FT (610mm)
4 FT (1.22m)
3 FT (914mm)
6 FT (1.86m)
4 FT (1.22m)
8 FT (2.48m)
5 FT (1.52m)
16 FT (4.8m)
H MAX. = 16 FT (4.8m)
VENTING WITH ONE (1) 90
MODELS: SL-350TRS-C, SL-550TRS-D, SL-750TRS-D
V (MIN.)
o
90
Elbow on Top
1 FT (305mm)
2 FT (610mm)
3 FT (914mm)
4 FT (1.22m)
5 FT (1.52m)
H MAX. = 16 FT (4.8m)
Figure 13. Venting with One 90° Elbow
24
H
2' MAX. (610mm)
4' MAX. (1.22m)
6' MAX. (1.86m)
8' MAX. (2.4m)
o
ELBOW
NATURAL GAS
MODELS: SL-550TRS-D, SL-750TRS-D
V + H MAX. = 40 FT (12.2m)
o
ELBOW
H (MAX.)
NOT ALLOWED
2 FT (610mm)
4 FT (1.22m)
6 FT (1.86m)
8 FT (2.48m)
16 FT (4.8m)
V + H MAX. = 40 FT (12.2m)
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06
V
H
H (MAX.)
2 FT (610mm)
3 FT (914mm)
4 FT (1.22m)
6 FT (1.86m)
8 FT (2.48m)
16 FT (4.8m)
PROPANE
H
V
NOTE: There MUST be a 25%
reduction in total H when using
flex vent except when using
the simple up and out installa-
tion (see Figure 9).