THESE PROCEDURES MUST BE FOLLOWED BY QUALIFIED PERSONNEL OR
WARRANTY WILL BE VOIDED.
GENERAL:
THE UNIT, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED AND COMPLY
WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL
ELECTRICAL CODE ANSI/NFPA 70-LATEST EDITION.
CANADIAN INSTALLATION MUST COMPLY WITH CSA-STANDARD C22.2 No. 0-M1982 -
General Requirements - Canadian Electrical Code, Part II. 109-M1981 - Commercial Cooking
Appliances.
NOTE: Electrical diagrams are located inside right hand compartment on back side of right hand side cover.
ELECTRICAL:
A Field Connection Terminal Block is located at the rear of the unit, lower left hand side, behind a small rectangular
cover which is secured with (1) screw. Adjacent to the cover, a hole is provided for a 3/4" conduit fitting (solid or flex).
Refer to Figure 1.