Extended Hoods
If your non-combustible facing material is over 1" in thickness that will be used to finish this firebox, an extended hood is available that will
extend out 2" farther out into the room. Contact your local dealer for details.
VB4H32BL
Standard Black
VB4H32BR
Polished Brass
VB4H32SS
Stainless Steel
VB4H32HP
Hammered Pewter
Finishing
All joints (top, bottom and sides), where the wall or decorative facing material meets the firebox surround should be sealed with a non-
combustible material.
Hearth extensions are recommended, but not required for these fireboxes.
The firebox is designed to accept a 3/8-inch gas line for an approved
vent-free gas logset. Have the line installed by a qualified service
person in accordance with all building codes. Consult local building
codes to properly size the gas supply line leading to the 3/8-inch
hook-up at the unit. The state of Massachusetts requires that a
flexible appliance connector cannot exceed three feet in length.
Gas access holes are provided on both sides of the firebox. See
Figure 11. On models with refractory brick panels installed,
carefully remove the knockout in the refractory brick panel using a
large standard screwdriver and hammer. First, place screwdriver in
groove next to plug and pry sideways to pop out main plug. Then
remove the remaining concrete in hole with gentle tapping with ball
peen hammer and/or screwdriver. A masonry drill and bit may also
be used to create a clean hole for the gas line to pass through.
See Figure 12.
When installing optional ceramic fiber side panels into firebox,
lay panel on a flat surface. Remove the gas line knockout (round
depression) in the appropriate side panel using a drill or utility knife.
After the brick panel knockout is removed, the firebox wrap may
have a round metal knockout that must be removed also. Use a
screwdriver to punch out the metal knockout.
Check gas type. Use only the gas type indicated on the gas log
set rating plate. If the gas listed on the plate is not your type of gas
supply, DO NOT INSTALL. Contact your dealer for proper model.
Always use an external regulator for all LP fireboxes to reduce the
supply tank pressure to a maximum of 14 inch w.c. This is in addition
to the regulator fitted to the log set.
WARNING: CONNECTION DIRECTLY TO AN UNREGULATED
L.P. TANK CAN CAUSE EXPLOSION.
Install only a ANSI Z21.11.2 vent-free log set into this firebox.
33637-0-0314

INSTALLING HOOD

VB4H36BL
Standard Black
VB4H36BR
Polished Brass
VB4H36SS
Stainless Steel
VB4H36HP
Hammered Pewter

GAS LINE CONNECTION

VB4H42BL
Standard Black
VB4H42BR
Polished Brass
VB4H42SS
Stainless Steel
VB4H42HP
Hammered Pewter
GAS ACCESS HOLES
Figure 11
Brick Panel
Figure 12
Page 9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents