Chapter 9 Operational Settings
Range
End
Displays the end position of the detection
(Middle)
by the length from the leading edge of the
document.
Range: 0 to 510 mm, in 2 mm increments,
Start<End
When both [Start] and [End] are set to "0", multifeed
detection is performed for the whole area regardless of
whether it is enabled or disabled.
To disable multifeed detection for the whole document,
select [Disable] and set the start position to "0" and the
end position to equal the document length or longer.
If you set a value larger than the document length for
the start position, selecting [Disable] detects the whole
length of the document and selecting [Enable] disables
the multifeed detection.
In order to detect multifeeds, the detection range must
be at least 5 mm long.
Configure the setting so that the value of the end
position minus the start position is 6 mm or more.
You can also set the start and the end positions by the
following methods:
- Draw an area with the mouse on the displayed
image.
- Drag the handles for [Start] and [End] positions on
the displayed image.
Example 1:
Description
Position: Middle
Selected range = Enable, Start = 50 mm, End = 200 mm
Multifeeds are detected for the area in light blue.
50
50
200
Unit: mm
TOP
Contents
Index
Introduction
Scanner
Overview
How to Load
Documents
Configuring the
Scan Settings
How to Use the
Operator Panel
Various Ways to
Scan
Daily Care
Replacing the
Consumables
Troubleshooting
Operational
Settings
Appendix
Glossary
148

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents