Wiring Diagram - Ashley 24AF Owner's Manual

Wood & coal burning furnace
Table of Contents

Advertisement

WIRING DIAGRAM

NOTE: RHEOSTAT IS ADJUSTABLE. IN CASE OF LOW VOLTAGE
TURN COUNTERCLOCKWISE UNTIL BLOWER WILL RUN, BUT
NOT STALL, WHEN POWER IS RETURNED TO UNIT.
ORANGE
RHEOSTAT
PT# 80090
(3)
PT# 80390
(LOCATED ON LEFT
(2)
PT# 80388
(LOCATED ON RIGHT
SIDE, TOP)
(1)
PT# 80389
(LOCATED ON RIGHT
SIDE, BOTTOM)
BLACK
BLUE
ORANGE
Page 20
Y
OF BOX)
BLUE
BROWN
BLACK
PURPLE
BLACK
PURPLE
DRAFT FAN
PT# 80392
ROOM
THERMOSTAT
BLUE
G
W
C
R
BLACK
RED
1
3
2
4
6
5
COIL
COIL
BLACK
RELAY
BOTTOM
BLACK
BLUE
WHITE
BLACK
BLUE
NOTE:
CAP OFF "RED"
WIRE WITH A
WIRE NUT.
THERMAL DISC
DISTRIBUTION FAN
(1) HI-SPEED PT# 80389
ENERGIZES WHEN UNIT IS
FIRED AGGRESSIVELY ONLY.
(2) LOW SPEED PT# 80388
ADJUSTABLE IN APPROX.
5 DEGREE STEPS. A LOW
SETTING TURNS BLOWER ON
SOONER.
Rotate here
with flat-blade
screwdriver
THERMAL DISC
FAN ADJUSTMENT
DRAFT FAN
(3) HI LIMIT PT# 80390
DE-ENERGIZES WHEN UNIT
REACHES TEMPERATURES OF
APPROX. 170 DEGREES
GREEN
WHITE
NOTE: WIRES FROM
DISTRIBUTION FAN
RUN DIRECTLY INTO
THE 4 x 4 JUNCTION
BOX.
DISTRIBUTION
120 VAC
60 Hz
15 AMPS
FAN
PT# C60456
USSC