Ensure that the ambient air temperature surrounding the workstation falls within the published
limit.
NOTE:
is a 1 C per 304.8 M (1000 FT) derating above 1524 M (5000 FT). So, at 3,048 M (10,000 FT),
the upper ambient air temperature limit is 30 C.
For cabinet installation, ensure adequate cabinet ventilation and ensure that the ambient
temperature within the cabinet does not exceed published limits.
Never restrict the incoming or outgoing airflow of the workstation by blocking any vents or air
intakes as shown in the following figure.
Figure 3-2

Setup procedures

WARNING!
— Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
— Plug the power cord in a grounded (earthed) outlet that is easily accessible.
To set up the workstation:
1.
After unpacking your HP Workstation, find workspace with the proper ventilation to set up the
system.
2.
Connect the mouse and keyboard to the workstation.
For connector location information, see the rear panel connector section for the workstation in
this document.
20
Chapter 3 Setting up the workstation
The ambient upper limit of 35 C is only good up to 1524 M (5000 FT) elevation. There
Proper workstation placement
To reduce the risk of electric shock or damage to your equipment: