For Boiler Control At Mb1 Measuring Point; Installation Of Tank Temperature Sensors - Buderus Logalux PL750 Installation And Maintenance Instruction

Solar combi-tank for dhw and space heating
Table of Contents

Advertisement

4
Tank Assembly
4.1.3
Installation of tank temperature sensor for
boiler control at MB
V Insert the solar temperature sensor [1] into the top of
the tank at location MB
1
Cover [3]. Push the sensor wire [2] the entire length of
the well until it meets resistance.
4.1.4

Installation of tank temperature sensors

M
– M
1
8
Absolutely make sure that the entire sensor surface is in
contact with the storage tank.
V Cover the contact surface with a thermo-conductive
paste.
V Snap the temperature sensor into the tension spring on
the storage tank so that the contact surface is smooth.
V Carefully secure the sensor wire
12
measuring point
1
next to the top Clean-out
Logalux PL750/2 S - Changes may be made following technical improvements!
1
AW/EZ
Fig. 9
Measuring point MB
1
Temperature sensor for boiler control
2
Sensor spring wire
3
Top clean-out cover
4
Flange
Fig. 10 Installation of the system sensors
(basic drawing)
1
Temperature Sensor
2
Tension Spring
2
MB
1
EZ/AW
3
4
6 720 615 217-12.1RS
1
1
2
6 720 615 217-14.1RS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Logalux pl750 2 s