Controls And Adjustments; A) Default Dip Switch Settings; B) Infrared Sensor Shutdown Delay (S1 Dip Switch 1, 2, 3) - Hoshizaki MODULAR CUBELET SERENITY SERIES FS-1022MLH-C Service Manual

Modular cubelet serenity series including condensing unit
Hide thumbs Also See for MODULAR CUBELET SERENITY SERIES FS-1022MLH-C:
Table of Contents

Advertisement

3. Controls and Adjustments

Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact
Hoshizaki Technical Support at 1-800-233-1940.

a) Default Dip Switch Settings

The S1 dip switch settings are factory-set to the following positions:
S1 Dip Switch No.
FS-1022MLH-C

b) Infrared Sensor Shutdown Delay (S1 dip switch 1, 2, 3)

Infrared sensor shutdown delay is the delay between the infrared sensor detecting ice
(yellow LED flashing or steady) and the start of the shutdown sequence. For dispenser
unit applications, the ice level at shutoff may need to be adjusted depending on the
dispenser agitation or dispense method. Increasing the shutdown delay setting allows for
a higher level of ice in the bin before the icemaker shuts down. For a typical dispenser
unit application, a 100-second shutdown delay is recommended. When used with a
standard Hoshizaki storage bin, any shutdown delay setting is acceptable.
Increasing the shutdown delay allows a higher level of ice in the dispensing
unit/storage bin before shutdown. This could lead to icemaker movement or ice
overflow.
S1 Dip Switch Setting
No. 1
OFF
OFF
OFF
OFF
1
2
ON
OFF OFF OFF OFF OFF
Normally off (factory use)
Mechanical Backup Bin Control Shutdown Delay
Bin Control Selector
Continuous Dispensing Timer
(DCM models only, do not adjust on modular icemakers)
Drain Frequency Control
Infrared Sensor Shutdown Delay
No. 2
No. 3
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
CAUTION
3
4
5
6
WARNING
Infrared Sensor Shutdown Delay
0 Seconds
100 Seconds (1.6 minutes) (Factory Default)
1100 Seconds (18.3 minutes)
1650 Seconds (27.5 minutes)
2200 Seconds (36.7 minutes)
0 Seconds
0 Seconds
19
7
8
9
10
ON
ON
OFF OFF

Advertisement