Sanitizing Procedure - Final - Hoshizaki MODULAR CUBELET SERENITY SERIES FS-1022MLH-C Service Manual

Modular cubelet serenity series including condensing unit
Hide thumbs Also See for MODULAR CUBELET SERENITY SERIES FS-1022MLH-C:
Table of Contents

Advertisement

3) Pour the sanitizing solution over the extruding head until the evaporator assembly and
the reservoir are full and the solution starts to overflow into the drain pan.
4) Remove the proximity switch from the chute assembly, then remove the chute assembly
from the icemaker.
5) Remove the packing at the bottom of the ice chute. Remove the 3 ties and the chute
insulation.
6) Remove the 2 baffles.
7) Remove the plate and the packing from the top of the ice chute, then remove the
backup bin control assembly by sliding it slightly towards the chute opening and lifting it
off.
8) Disassemble the backup bin control assembly by removing the 2 snap pins, shaft, and
actuator.
9) Soak the spout, O-ring, packings, chute, baffles, plate, and backup bin control assembly
in the sanitizing solution for 10 minutes then wipe them down.
10) Rinse the parts thoroughly with clean water.
If the solution is left on these parts, they will rust.
11) Replace all parts in their correct positions.
When installing the baffles, make sure that the bent surface (the one without
the studs) faces the actuator so that the bent surface can guide the ice to the
center of the actuator.
12) Replace all panels except the front panel in their correct positions. Move the control
switch to the "ICE" position, then plug the unit back in. Move the power switch to the
"ON" position, then replace the front panel in its correct position. Make ice using the
solution until the icemaker stops making ice.
13) Remove the front panel, then move the power switch to the "OFF" position. Move the
control switch to the "DRAIN" position, then move the power switch back to the "ON"
position. Replace the front panel in its correct position.
14) Allow the water system to drain for 5 minutes.
15) Remove the front panel. Move the power switch to the "OFF" position, then unplug the
unit from the electrical outlet.

5. Sanitizing Procedure - Final

1) Mix a new batch of the sanitizing solution.
2) Make sure the power switch is in the "OFF" position, the unit is unplugged from the
electrical outlet, and the water supply line shut-off valve is closed. Remove the top
panel.
3) Remove the strap connecting the spout to the chute assembly, then remove the spout.
CAUTION
IMPORTANT
54