Philips 170C6FS/00 Service Manual page 46

17 inch tft lcd colour monitor
Hide thumbs Also See for 170C6FS/00:
Table of Contents

Advertisement

46
Step 2: Installation of EDID45.1.EXE
Start Microsoft Windows.
1.The Program"EDID45.1.EXE" in service manual cd-rom be copyed
to C:\ .
2.Click"
" choose Run at start menu of Windows as shown
In Fig. 5.
3. At the submenu, type the letter of your computer's hard disk drive
followed by :EDID45
(for example, C:\EDID45, as shown in Fig. 6).
EDID45
OK
4. Click
button. The main menu appears (as shown in Fig. 7).
Note 2: During the loading, EDID45 will verify the EDID data which just
loaded from monitor before proceed any further function, once
the data structure of EDID can not be recognized, the following
error message will appear on the screen as below. Please
Confirm following steps to avoid this message.
1. The data structure of EDID was incorrect.
2. DDC IC that you are trying to load data is empty.
3. Wrong communication channel has set at configuration setup
windows.
4. Cables loosed or poor contact of connection.
1
DDC Instructions
Step 3: Read DDC data from monitor
1. Click
The Channels "Configuration Setup" windows as shown in Fig. 8
2.
Select the DDC2Bi as the communication channel.
As shown in Fig. 8.
3. Click OK button to confirm your selection.
Fig. 5
4. Click
monitor. The EDID codes will display on screen as shown in Fig.9
Fig. 6
Step 4: Modify DDC data (verify EDID version, week, year)
1.
Click
Step 1 of 9 as shown in Fig. 10-18 .
EDID45 DDC application provides the function selection and
text change (select & fill out) from Step 1 to Step 9.
Fig. 7
Select and fill out,
If necessary.
Fig. 8
icon as shown in Fig. 7 from the tool bar to bring up
icon (Read EDID function) to read DDC EDID data from
(new function) icon from the tool bar, bring up
Fig. 10
Fig. 8
Fig. 9