Checking The Version Number; Test Mode - Roland CUBE 30 Service Notes

Hide thumbs Also See for CUBE 30:
Table of Contents

Advertisement

Jul.2002
CHECKING THE VERSION
NUMBER
1.
Connection of foot switches
Connect two FS-5U foot switches to the [FOOT.SW] terminals with the
PCS-31 foot switch cable. See "How to set the foot switch FS-5U".
[polarity] setting for FS-5U foot switch
Set the [polarity] switch to the jack side.
Cable of connections for foot switch
The PCS-31 connection cable for the foot switch is a conversion cable
connecting a stereo plug and two standard plugs. Connect the standard
plugs to the foot switches.
The "white" side of the standard plug is used to change JC CLEAN and
LEAD of [SELECT].
The "red side" of the standard plug is used to switch [EFX] on and off.
TIP and RING of the stereo (TRS) plugs of the PCS-31 correspond to
SELECT and EFX, respectively.
2.
Setting up of the panel
Set the LEAD CH rotary switch to "ACOUSTIC", and all other knobs to
"0" or "off".
Undepress the [SELECT] button to JC CLEAN (to green LED when the
power is on).
3.
How to check the version number
After completing 1) and 2), turn on the power while pressing the foot
switch for SELECT switching (white side). Then within four seconds,
press it again twice to start the test mode.
As soon as the test mode starts, all LEDs blink several times, then some
LEDs blink to display the version number (see the following on how to
display the version number).
If setting up of the panel in 2) is not done correctly, the test mode cannot be
started.
4.
How to display the version number
The version number is displayed by the blinking/off combination of the
green and red LEDs of [SELECT], the red LED of [EFX] ON/OFF.
LEDs used for display
[JC CLEAN] Green LED
[LEAD]
Red LED
[EFX]
Red LED
5.
Turn off this unit
10
. . .
1.00
1.01
1.02
1.03
❍ : Blinking
● : Off.

TEST MODE

1 What is needed
• Headphones 1 set
• Foot switch BOSS FS-5U (Optional) 2 units
• Connection cable for foot switch ROLAND PCS-31 (Optional) 1 unit
2 How to enter the test mode
1.
Connection of foot switches
Connect two FS-5U foot switches to the [FOOT.SW] terminals with the
PCS-31 foot switch cable (See CHECKING THE VERSION NUMBER
1. Connection of foot switches).
2.
Setting up of the panel
Set the LEAD CH rotary switch to "ACOUSTIC", and all other knobs to
"0" or "off".
Undepress the [SELECT] button to JC CLEAN (to green LED when the
power is on).
3.
How to enter the test mode
After completing 1) and 2), turn on the power while pressing the foot
switch for SELECT switching (white side). Then within four seconds,
press it again twice to start the test mode.
As soon as the test mode starts, all LEDs blink several times, then some
LEDs blink to display the version number (see the following on how to
display the version number).
Confirm here that all LEDs can be turned on to show the succeeding
check results correctly.
If setting up of the panel in 2) is not done correctly, the test mode cannot be
started.
3 How to exit the test mode
Turn off the power to exit the test mode.
4 Skipping
The check mode cannot be skipped.
5 Test items
1)
DSP check: (automatically judged)
2)
Switch check:
3)
Volume check: