Sharp AR-M160 Service Manual page 37

Sharp digital copier service manual
Hide thumbs Also See for AR-M160:
Table of Contents

Advertisement

Main
Sub
Contents
code
code
26
38
Cancel of stop at drum life over
39
Memory capacity check
42
Transfer ON/OFF timing control
setting
43
Side void amount setting
51
Copy temporary stop function
setting
30
01
Paper sensor status display
42
01
Developing counter clear
When this simulation is executed, the current set code number is displayed. Enter the desired code
number and press the [START] key to set the code number.
Code number
0
1
When this simulation is executed, the current memory capacity is displayed.
7-seg display
16
32
When this simulation is executed, the current setting value of transfer ON timing is displayed.
Enter a set value and press the [START] key to set the entered value, and the machine will go into
the sub code input standby mode.
When the [Mode select] key is pressed, the ON timing setting and the OFF timing setting are
alternatively selected. At that time, the setting is saved and written into the EEPROM.
Display lamp
AE mode lamp
TEXT mode lamp
•Setting range: 1 ~ 99
When the setting value is increased by 1, time is increased by 2ms.
•The default, 50, of transfer ON timing means "344ms passed from PS release."
The default, 50, of transfer OFF timing means "304ms passed from P-IN OFF."
Used to set the side void amount on the both sides.
Enter a set value with the 10-key and press the [START] key, and the entered value will be saved and
the machine will go into the sub code input standby mode.
The setting range is 0 ~ 10. When the set value is increased by 1, the void amount is increased by
0.5mm. The default is 3 (= 1.5mm).
To select the setting mode, press the [Exposure mode select] key. The set value of the selected
mode is displayed on the copy quantity display. At that time, the set value is also saved.
Display lamp
AE mode lamp
TEXT mode lamp
*
When the setting value is increased by 1, time is increased by 0.5ms.
When any key is pressed, it is displayed on the display section. When the [START] key is pressed,
the set code data is acquired and stored to the setting variable of sort/group copy temporary stop
function and to the EEPROM. The machine goes into the sub code input standby mode.
Code number
0
1
When the [Interrupt] key is pressed at that time, the machine goes into the sub code input standby
mode without rewriting the data. When the [CA] key is pressed, the simulation mode is terminated
without rewriting the data.
*
When this is set to "Stop," temporary stop is made for every 250 copies in one copy job.
The paper sensor status is displayed with the lamps on the operation panel.
*
When each sensor detects paper, the corresponding lamp turns on.
Display lamp
Developer lamp
Machine jam lamp
Toner lamp
Manual paper feed lamp
No. 1 cassette lamp
No. 2 cassette lamp
No. 3 cassette lamp
No. 4 cassette lamp
Tray jam lamp 1
Tray jam lamp 2
Paper empty lamp
The developer counter data in the EEPROM is cleared and 0 is displayed on the 7-seg display.
When the [Interrupt] key is pressed at that time, the machine goes into the sub code input standby
mode. When the [CA] key is pressed, the simulation mode is terminated.
AR-M205 SIMULATIONS 7-10
Details of operation
Setting
Stop at drum life over
Cancel of stop at drum life over
Meaning (Memory capacity)
16MByte
32MByte
Setting mode
Transfer ON timing
Transfer OFF timing
Side void amount (Right)
Side void amount (Left)
Setting
Not stop
Stop
Paper exit sensor
Duplex sensor
Paper entry sensor
Manual feed paper empty sensor
No. 1 tray paper empty sensor
No. 2 tray paper empty sensor
No. 3 tray paper empty sensor
No. 4 tray paper empty sensor
No. 2 tray paper feed sensor
No. 3 tray paper feed sensor
No. 4 tray paper feed sensor
Default
50
50
Setting mode
* Default
Sensor name