3. FM MONO DISTORTION ADJUSTMENT

AC VOLT METER ........................Connect to the output.
Signal Generator........................Connect to FM ANT Jack (FM IN) through the dummy.
Distortion Meter .........................Connect to the output.

4. FM/AM AUTO STOP LEVEL CHECK

FM SIGNAL GENERATOR ........................Connect to FM ANT Jack (FM IN) through the dummy
AM SIGNAL GENERATOR.........................Connect to AM ANT, Coil through the Loop antenna
BAND
STEP
SIGNAL GENERATOR
90.10MHz [EUR,US]
1
78.00MHz [J]
FM
106.10MHz [EUR,US]
2
88.00MHz [J]
1
AM
2
AC
NO.
612kHz [EUR,J]
610kHz [US]
1404kHz [EUR,J]
1400kHz [US]
Frequency
98.10MHz [EUR,US]
1
82.00MHz [J]
Check
32dB
TUNED
32dB
TUNED
84dB
TUNED
84dB
TUNED
7
Adjust for
Adjustment
Minimum T.H.D
FE001
(<1%)
Result
OK/NG
OK/NG
OK/NG