FOR DISCOUNT PARTS CALL 606-678-9623 OR 606-561-4983
A.C.2
Test #
1
2
3
4
5
6
7
8
9
10
11
12
www.mymowerparts.com
A.C.1 B+
Figure 7.37
Pos. Probe
COM. Probe
Housing
B+
Housing
A.C. 1
Housing
A.C.2
B+
A.C.1
B+
A.C.2
B+
Housing
A.C.1
B+
A.C.1
A.C.2
A.C.1
Housing
A.C.2
B+
A.C.2
A.C.1
A.C.2
Housing
7b. Bench Test: See Figure 7.37.
• Set a digital multi-meter to read on the X100Ω
scale.
• With the key OFF and the fuse removed, unplug all
the wires from the regulator/rectifier.
• Remove the regulator/rectifier from the engine (not
strictly necessary, but provides easy access).
• Make the resistance tests described in the accom-
panying table.
B+
is the D.C. terminal
A.C.1
is the A.C. terminal nearest B+
A.C.2
is the A.C. terminal furthest from B+
8.
If the regulator/rectifier fails any one of these tests,
replace it with a new one.
Results
O.L. (infinite resistance)
O.L. (infinite resistance)
> 1.0 Ω (5 second delay)
0 Ω (Perfect continuity)
> 1.0 Ω
> 1.0 Ω
0 Ω (Perfect continuity)
> 1.0 Ω
> 1.0 Ω
O.L. (infinite resistance)
O.L. (infinite resistance)
> 1.0 Ω
Electrical