MTD 700 Series Professional Shop Manual page 116

700 series riding tractors
Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

FOR DISCOUNT PARTS CALL 606-678-9623 OR 606-561-4983
Series 700 Lawn Tractor
Reverse safety circuit
The reverse circuit functions the same for all of the electrical systems used on the 700 series tractors.
See Figure 7.26.
No OCR
When the transmission put into reverse, the shift linkage will contact the reverse switch, applying a ground
to it.
The ground signal will travel to a N.O terminal of the PTO switch through a yellow wire wit a black trace.
If the PTO is ON, the contacts will close and sent the ground signal to the magneto through the yellow wire
and shut down the engine.
7 and 8 pin OCR
When the transmission put into reverse, the shift linkage will contact the reverse switch, applying a ground
to it.
The ground signal will travel to the REV SW terminal of the OCR module through a red wire with a a black
trace.
If the module is in the mow in reverse mode, the reverse switch is "unplugged" and the signal stops there.
If the module is not in the mow in reverse mode, the ground signal passes through the module to the PTO
switch through a yellow wire wit a black trace.
If the PTO is ON, the contacts will close and sent the ground signal to the magneto through the yellow wire
and shut down the engine.
110
www.mymowerparts.com
Figure 7.26

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

13an772g00013wx78ks01113ar791g790

Table of Contents