4-3-2. POWER PCB

Rating : AC100~240 V, Single-Phase
Regulation Method : Transistor & Switching Method
Rating Input Frequency : 50~60Hz, Inrush Current : under 35A.
Output Voltage is as follows.
Rating Variable
(V)
1
Vsus
175
2
Vadd
70
3
Vyer
160
4
Vdr1
15.5
5
V1
5
6
V2
12
7
V3
17
-17
8
V4
5.1
9
V5
3.6
10
Vstb
5
* When Protect Circuit operates, all Outputs except Vstb are suspended. But, when
Vstb is abnormal, all Outputs are suspended.
* OVP(Over Voltage Protection), OCP(Over Current Protection)
The above table s Output Voltage output from the following connector.
(based on the Parts Side s silk name of POWER PCB)
Vsus
Vsus
Vyer
NC
P2
NC
NC
VG
VG
V4
P4
VG
VG
V5
NC
NC
Voltage(Vdc)
Allowable
Tolerance
Range
overshoot
(V)
(V)
Voltage(V)
10
200
10
10
180
0.75
0.25
0.6
13.6
0.75
0.75
-18
0.55
0.33
3.66
0.5
HG
HG
Vdr1
Vstd
VG
NC
P5
NC
PR
Ripple
OVP
Voltage
(V)
(mVp-p)
200
2000
90
100
500
500
18
18
50
6
50
50
18
50
50
6.5
50
33
6
50
NC
Vsus Vsus
NC
LG
LG
V2
V2
NC
P3
LG
LG
V1
V1
-31-
Ripple Noise
Rating
Voltage
(A)
(mVp-p)
500
1.5
300
1
500
0.1
100
1
100
1
100
0.6
100
0.7
100
0.7
100
1
66
1
100
0.5
HG
HG
HG
HG
Vadd
P1
V3
P6
SG
SG
V3
Current(Adc)
When
OCP
Lode
(A)
change
0.1~1.5 Over 3.2
0.1~1 Over 2.0
0~0.15
0.1~1
1.4
0.1~1
0~1
0~1
0.1~1
0.1~1
0~1
0~1
HG
Vdr1

Hide quick links: