  • Page 2 The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. Exhaust contains poisonous carbon monoxide gas that can build up to dangerous levels in closed areas. Breathing carbon monoxide can cause unconsciousness or death.
  • Page 3 INTRODUCTION Congratulations on your selection of a Honda generator. We are certain you will be pleased with your purchase of one of the finest generators on the market. We want to help you get the best results from your new generator and to operate it safely.
  • Page 4 A FEW WORDS ABOUT SAFETY Your safety and the safety of others are very important. And using this generator safely is an important responsibility. To help you make informed decisions about safety, we have provided operating procedures and other information on labels and in this manual.
  • Page 5: Table Of Contents

    CONTENTS GENERATOR SAFETY ................IMPORTANT SAFETY INFORMATION ..........Operator Responsibility ..............Carbon Monoxide Hazards ..............Electric Shock Hazards ............... Fire and Burn Hazards ................ Refuel With Care ................. SAFETY LABEL LOCATIONS ..............CONTROLS & FEATURES ................ COMPONENT & CONTROL LOCATIONS ...........
  • Page 6 CONTENTS OPERATION ....................SAFE OPERATING PRECAUTIONS ............. STARTING THE ENGINE ..............STOPPING THE ENGINE ..............AC OPERATION ..................AC Applications ................. AC PARALLEL OPERATION ..............AC Parallel Operation Applications ..........DC OPERATION ..................ECO-THROTTLE SYSTEM ..............STANDBY POWER ................Connections to a Building’s Electrical System .......
  • Page 7 CONTENTS TRANSPORTING ..................TAKING CARE OF UNEXPECTED PROBLEMS ........ENGINE WILL NOT START ..............ENGINE LACKS POWER ............... NO POWER AT THE AC RECEPTACLES ..........NO POWER AT THE DC RECEPTACLE ..........TECHNICAL & CONSUMER INFORMATION .......... TECHNICAL INFORMATION ..............Serial Number Location ..............
  • Page 8: Generator Safety

    GENERATOR SAFETY IMPORTANT SAFETY INFORMATION Honda generators are designed for use with electrical equipment that has suitable power requirements. Other uses can result in injury to the operator or damage to the generator and other property. Most injuries or property damage can be prevented if you follow all instructions in this manual and on the generator.
  • Page 9: Electric Shock Hazards

    GENERATOR SAFETY Electric Shock Hazards The generator produces enough electric power to cause a serious shock or electrocution if misused. Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet, could result in electrocution.
  • Page 10: Refuel With Care

    GENERATOR SAFETY Refuel With Care Gasoline is extremely flammable, and gasoline vapor can explode. Allow the engine to cool if the generator has been in operation. Refuel only outdoors in a well-ventilated area with the engine off. Do not overfill the fuel tank. Never smoke near gasoline, and keep other flames and sparks away.
  • Page 11: Safety Label Locations

    GENERATOR SAFETY SAFETY LABEL LOCATIONS These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your Honda servicing dealer for a replacement. California type Non-California type...
  • Page 12 GENERATOR SAFETY...
  • Page 13: Controls & Features

    CONTROLS & FEATURES COMPONENT & CONTROL LOCATIONS Use the illustrations on these pages to locate and identify the most frequently used controls. PARALLEL OPERATION OUTLETS AC RECEPTACLES ECO-THROTTLE SWITCH GROUND TERMINAL OIL ALERT INDICATOR OVERLOAD INDICATOR OUTPUT INDICATOR DC RECEPTACLE DC CIRCUIT PROTECTOR FUEL TANK CAP VENT LEVER CHOKE LEVER...
  • Page 14 CONTROLS & FEATURES SPARK PLUG MAINTENANCE COVER SPARK PLUG MUFFLER...
  • Page 15: Controls

    CONTROLS & FEATURES CONTROLS Engine Switch ENGINE SWITCH The engine switch controls the ignition system and the fuel valve. Stops the engine and closes the fuel valve. Running position; opens the fuel valve and allows the engine to be started. Starter Grip Pulling the starter grip operates the recoil starter to crank the...
  • Page 16: Fuel Tank Cap Vent Lever

    CONTROLS & FEATURES Fuel Tank Cap Vent Lever The fuel tank cap is provided with a vent lever to seal the fuel tank. The vent lever must be in the ON position for the engine to run. When the engine is not in use, leave the vent lever in the OFF position to reduce the possibility of fuel leakage.
  • Page 17: Eco-Throttle Switch

    CONTROLS & FEATURES Eco-Throttle Switch The Eco-Throttle system automatically reduces engine speed when loads are turned off or disconnected. When appliances are turned on or reconnected, the engine returns to the proper speed to power the electrical load. If high electrical loads are connected simultaneously, turn the Eco-Throttle switch to the OFF position to reduce voltage changes.
  • Page 18: Dc Receptacle

    CONTROLS & FEATURES DC Receptacle The DC receptacle should ONLY be used for charging 12-volt automotive type batteries. The DC charging output is not regulated. DC Circuit Protector The DC circuit protector automatically shuts off the DC battery charging circuit when the DC charging circuit is overloaded, when there is a problem with the battery, or when the connections between the battery and the generator are improper.
  • Page 19: Features

    CONTROLS & FEATURES FEATURES Output Indicator The output indicator (green) is illuminated when the generator is operating normally. It indicates that the generator is producing electrical power at the receptacles. In addition, the output indicator has a simplified hour meter function. When you start the engine, the indicator blinks according to the generator’s cumulative operating hours as follows: No blinks:...
  • Page 20: Oil Alert Indicator

    CONTROLS & FEATURES Oil Alert Indicator The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase can fall below a safe limit, the Oil Alert indicator (red) comes on and the Oil Alert system automatically will stop the engine (the engine switch will remain in the ON position).
  • Page 21: Before Operation

    BEFORE OPERATION ARE YOU READY TO GET STARTED? Your safety is your responsibility. A little time spent in preparation will significantly reduce your risk of injury. Knowledge Read and understand this manual. Know what the controls do and how to operate them. Familiarize yourself with the generator and its operation before you begin using it.
  • Page 22: Check The Engine

    BEFORE OPERATION To prevent a possible fire, keep the generator at least 3 feet (1 meter) away from building walls and other equipment during operation. Do not place flammable objects close to the engine. Before beginning your pre-operation checks, be sure the generator is on a level surface and the engine switch is in the OFF position.
  • Page 23: Operation

    OPERATION SAFE OPERATING PRECAUTIONS Before operating the generator for the first time, review chapters GENERATOR SAFETY (see page ) and BEFORE OPERATION (see page For your safety, do not operate the generator in an enclosed area such as a garage. Your generator’s exhaust contains poisonous carbon monoxide gas that can collect rapidly in an enclosed area and cause illness or death.
  • Page 24: Starting The Engine

    OPERATION STARTING THE ENGINE To prevent a possible fire, keep the generator at least 3 feet (1 meter) away from building walls and other equipment during operation. Do not place flammable objects close to the engine. Operating this generator less than 3 feet (1 meter) from a building or other obstruction can cause overheating and damage the generator.
  • Page 25 OPERATION Make sure the Eco-Throttle ECO-THROTTLE SWITCH switch is in the OFF position, or more time will be required for warm-up. To start a cold engine, move the CHOKE LEVER choke lever to the CLOSED position. To restart a warm engine, leave the choke lever in the OPEN position.
  • Page 26 OPERATION Pull the starter grip lightly until you feel resistance, then pull briskly in the direction of the arrow as shown. STARTER GRIP Do not allow the starter grip to snap back against the generator. Return it gently to prevent damage to the starter. If the choke lever was moved to CHOKE LEVER the CLOSED position to start...
  • Page 27: Stopping The Engine

    OPERATION STOPPING THE ENGINE To stop the engine in an emergency, simply turn the engine switch to the OFF position. Under normal conditions, use the following procedure. Turn off or disconnect all appliances connected to the generator. Turn the engine switch to the OFF position. ENGINE SWITCH Allow the engine to cool, and then turn the fuel tank cap vent lever to the OFF position.
  • Page 28 OPERATION If two generators were connected for parallel operation, disconnect the parallel operation cables after stopping the engines if you do not wish to resume parallel operation. PARALLEL OPERATION CABLES (optional equipment)
  • Page 29: Ac Operation

    OPERATION AC OPERATION Before connecting an appliance to the generator, make sure that it is in good working order and that its electrical rating does not exceed that of the generator. Most motorized appliances require more than their electrical rating for startup.
  • Page 30 OPERATION Plug in the appliance into the receptacle. Turn on the appliance. If the generator is overloaded (see page ), or if there is a short circuit in a connected appliance, the overload indicator (red) will go ON. The overload indicator (red) will stay ON, and after about four seconds, current to the connected appliance(s) will shut off, and the output indicator (green) will go OFF.
  • Page 31: Ac Applications

    OPERATION AC Applications Before connecting an appliance or power cord to the generator: Make sure that it is in good working order. A faulty appliance or power cord can create a potential for electrical shock. If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn it off immediately.
  • Page 32: Ac Parallel Operation

    OPERATION AC PARALLEL OPERATION Before connecting an appliance to either generator, make sure that the appliance is in good working order and that its electrical rating does not exceed that of the receptacle. Most motorized appliances require more than their electrical rating for startup.
  • Page 33 OPERATION Plug in the appliance following the instruction provided with the parallel operation cables. Turn on the appliance. If the generators are overloaded (see page ), or if there is a short circuit in a connected appliance, the overload indicator (red) will go ON.
  • Page 34: Ac Parallel Operation Applications

    OPERATION AC Parallel Operation Applications Follow the instructions included with the parallel operation cables. Before connecting an appliance or power cord to the generator: Make sure that it is in good working order. A faulty appliance or power cord can create a potential for electrical shock. If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn it off immediately.
  • Page 35 OPERATION Limit operation requiring maximum power to 30 minutes. Maximum power in parallel operation is: 2.0 kVA For continuous operation, do not exceed the rated power. Rated power in parallel operation is: 1.8 kVA The total power requirements (VA) of all appliances connected must be considered.
  • Page 36: Dc Operation

    OPERATION DC OPERATION The DC receptacle should ONLY be used for charging 12-volt automotive type batteries. The DC charging output is not regulated. When using the DC output, turn the Eco-Throttle switch to the OFF position. Connecting the battery charging cable (optional equipment): Before connecting the battery charging cable to a battery that is installed in a vehicle, disconnect the vehicle battery ground cable from the negative ( ) battery terminal.
  • Page 37 OPERATION Connect the red lead of the battery charging cable to the positive ( ) battery terminal and the black lead to the negative ( ) battery terminal. DC CIRCUIT PROTECTOR DC RECEPTACLE Start the generator (see page Do not start the vehicle while the battery charging cable is connected and the generator is running.
  • Page 38 OPERATION Disconnecting the battery charging cable (optional equipment): Stop the engine. Disconnect the black lead of the battery charging cable from the negative ( ) battery terminal. Disconnect the red lead of the battery charging cable from the positive ( ) battery terminal. Disconnect the battery charging cable from the DC receptacle of the generator.
  • Page 39: Eco-Throttle System

    OPERATION ECO-THROTTLE SYSTEM With the switch in the ON position, engine speed is automatically lowered when loads are reduced, turned off, or disconnected. When appliances are turned on or reconnected, the engine returns to the proper speed to power the electrical load. In the OFF position, the Eco-Throttle system does not operate.
  • Page 40: Standby Power

    OPERATION STANDBY POWER Connections to a Building’s Electrical System Connections for standby power to a building’s electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes.
  • Page 41: Special Requirements

    OPERATION Special Requirements Do not lay the generator on its side when moving, storing, or operating it. Oil may leak and damage the engine or your property. There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator.
  • Page 42: Servicing Your Generator

    SERVICING YOUR GENERATOR THE IMPORTANCE OF MAINTENANCE Good maintenance is essential for safe, economical, and trouble free operation. It will also help reduce air pollution. To help you properly care for your generator, the following pages include a maintenance schedule, routine inspection procedures, and simple maintenance procedures using basic hand tools.
  • Page 43: Maintenance Safety

    SERVICING YOUR GENERATOR MAINTENANCE SAFETY Some of the most important safety precautions follow. However, we cannot warn you of every conceivable hazard that can arise in performing maintenance. Only you can decide whether or not you should perform a given task. Failure to properly follow maintenance instructions and precautions can cause you to be...
  • Page 44: Maintenance Schedule

    SERVICING YOUR GENERATOR MAINTENANCE SCHEDULE REGULAR SERVICE PERIOD (3) First Every Every Every Perform at every indicated month Each month 2 years or operating hour interval, months months Page whichever comes first. 10 Hrs. 300 Hrs. ITEM 50 Hrs. 100 Hrs. Engine oil Check level Change...
  • Page 45: Refueling

    SERVICING YOUR GENERATOR REFUELING With the engine stopped, remove the fuel tank cap and check the fuel level. Refill the fuel tank if the fuel level is low. Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel.
  • Page 46: Fuel Recommendations

    SERVICING YOUR GENERATOR FUEL RECOMMENDATIONS This engine is certified to operate on regular unleaded gasoline with a pump octane rating of 86 or higher. Never use stale or contaminated gasoline or an oil/gasoline mixture. Avoid getting dirt or water in the fuel tank. You may use regular unleaded gasoline containing no more than 10% ethanol (E10) or 5% methanol by volume.
  • Page 47: Engine Oil Level Check

    SERVICING YOUR GENERATOR ENGINE OIL LEVEL CHECK Check the engine oil level with the generator on a level surface and the engine stopped. Loosen the cover screw and remove the maintenance cover. COVER SCREW MAINTENANCE COVER...
  • Page 48 SERVICING YOUR GENERATOR Remove the oil filler cap and wipe the dipstick clean. Check the oil level by inserting the dipstick into the oil filler neck without screwing it in. If the level is low, fill with the recommended oil (see page ) to the upper limit of the oil filler neck.
  • Page 49: Engine Oil Change

    SERVICING YOUR GENERATOR ENGINE OIL CHANGE Drain the oil while the engine is warm to assure rapid and complete draining. Turn the engine switch and fuel tank cap vent lever to the OFF position (see page ) to reduce the possibility of fuel leakage. Loosen the cover screw and remove the maintenance cover (see page 45 ).
  • Page 50: Engine Oil Recommendations

    SERVICING YOUR GENERATOR ENGINE OIL RECOMMENDATIONS Oil is a major factor affecting performance and service life. Use 4-stroke automotive detergent oil. SAE 10W 30 is recommended for general use. Other viscosities shown in the chart may be used when the average temperature in your area is within the recommended range.
  • Page 51: Air Cleaner Service

    SERVICING YOUR GENERATOR AIR CLEANER SERVICE COVER SCREW Loosen the cover screw and remove the maintenance cover. Press the latch tab on the top of the air cleaner case, and remove the air cleaner cover. Check the foam air filter to be sure it is clean and in good condition.
  • Page 52: Foam Air Filter Cleaning

    SERVICING YOUR GENERATOR FOAM AIR FILTER CLEANING A dirty foam air filter will restrict air flow to the carburetor, reducing engine performance. If you operate the generator in very dusty areas, clean the foam air filter more frequently than specified in the Maintenance Schedule (see page Wash the foam air filter in a solution of household detergent and warm water, then rinse thoroughly, or wash in non-flammable or...
  • Page 53: Spark Plug Service

    SERVICING YOUR GENERATOR SPARK PLUG SERVICE In order to service the spark plug, you will need a spark plug wrench (commercially available). Recommended spark plug: LR4C-E (NGK) To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. An incorrect spark plug can cause engine damage.
  • Page 54 SERVICING YOUR GENERATOR Inspect the spark plug. Replace SIDE ELECTRODE it if the electrodes are worn or if the insulator is cracked, SEALING WASHER chipped, or fouled. 0.024 0.028 in (0.6 0.7 mm) Measure the spark plug electrode gap with a wire-type feeler gauge.
  • Page 55: Spark Arrester Service

    SERVICING YOUR GENERATOR SPARK ARRESTER SERVICE The spark arrester must be serviced every 100 hours to keep it functioning as designed. If the engine has been running, the muffler will be very hot. Allow the muffler to cool before servicing the spark arrester. Clean the spark arrester as follows: Remove the four 5 mm screws, and remove the muffler protector.
  • Page 56 SERVICING YOUR GENERATOR Use a brush to remove carbon deposits from the spark arrester screen. Be careful to avoid damaging the screen. The spark arrester must be free of breaks and tears. Replace the spark arrester if it is damaged. Check the muffler gasket;...
  • Page 57: Storage

    STORAGE STORAGE PREPARATION Proper storage preparation is essential for keeping your generator trouble-free and looking good. The following steps will help to keep rust and corrosion from impairing your generator’s function and appearance, and will make the engine easier to start when you use the generator again.
  • Page 58 STORAGE Service according to the table below: STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO PREVENT HARD STARTING Less than 1 month No preparation required 1 to 2 months Fill with fresh gasoline and add gasoline stabilizer . 2 months to 1 year Fill with fresh gasoline and add gasoline stabilizer .
  • Page 59 STORAGE Draining the Carburetor Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel. Stop the engine and keep heat, sparks, and flame away. Handle fuel only outdoors. Wipe up spills immediately. Loosen the cover screw and remove the maintenance cover (see page 45).
  • Page 60 STORAGE Draining the Fuel Tank and Carburetor Gasoline is highly flammable and explosive. You can be burned or seriously injured when handling fuel. Stop the engine and keep heat, sparks, and flame away. Handle fuel only outdoors. Wipe up spills immediately. Unscrew the fuel tank cap (see page 43), remove the debris screen, and empty the fuel tank into an approved gasoline container.
  • Page 61: Engine Oil

    STORAGE Engine Oil Change the engine oil (see page 47). Remove the spark plug (see page 51), and apply a couple of drops of clean engine oil into the cylinder. Crank the engine several revolutions to distribute the oil, then reinstall the spark plug. Reinstall the spark plug cap on the spark plug securely.
  • Page 62: Storage Precautions

    STORAGE STORAGE PRECAUTIONS If your generator will be stored with gasoline in the fuel tank and carburetor, it is important to reduce the hazard of gasoline vapor ignition. Select a well ventilated storage area away from any appliance that operates with a flame, such as a furnace, water heater, or clothes dryer. Also avoid any area with a spark-producing electric motor, or where power tools are operated.
  • Page 63: Transporting

    TRANSPORTING Do not lay the generator on its side when moving, storing, or operating it. Oil may leak and damage the engine or your property. If the generator has been used, allow it cool for at least 15 minutes before loading the generator on the transport vehicle. A hot engine and exhaust system can burn you and can ignite some material.
  • Page 64: Taking Care Of Unexpected Problems

    TAKING CARE OF UNEXPECTED PROBLEMS ENGINE WILL NOT START Possible Cause Correction Fuel tank cap vent lever OFF. Turn lever ON (p. 22). Engine switch OFF. Turn engine switch to ON (p. 23). Out of fuel. Refuel (p. 43). Bad fuel; generator stored Drain fuel tank and carburetor without treating or draining (p.
  • Page 65: Engine Lacks Power

    TAKING CARE OF UNEXPECTED PROBLEMS ENGINE LACKS POWER Possible cause Correction Air filter restricted. Clean or replace air filter (p. 49, 50). Bad fuel; generator stored Drain fuel tank and carburetor without treating or draining (p. 58). gasoline, or refueled with bad Refuel with fresh gasoline gasoline.
  • Page 66: No Power At The Ac Receptacles

    TAKING CARE OF UNEXPECTED PROBLEMS NO POWER AT THE AC RECEPTACLES Possible Cause Correction Output indicator is OFF, and Check AC load. Stop and restart overload indicator is ON. the engine. Check the cooling air inlet. Stop and restart the engine. Faulty power tool or Replace or repair power tool or appliance.
  • Page 67: Technical & Consumer Information

    TECHNICAL & CONSUMER INFORMATION TECHNICAL INFORMATION Serial Number Location FRAME SERIAL NUMBER Record the frame serial number and date purchased in the spaces below. You will need this information when ordering parts, and when making technical or warranty inquiries. Frame serial number: Date purchased:...
  • Page 68: Carburetor Modification For High Altitude Operation

    TECHNICAL & CONSUMER INFORMATION Carburetor Modification for High Altitude Operation At high altitude, the standard carburetor air-fuel mixture will be too rich. Performance will decrease, and fuel consumption will increase. A very rich mixture will also foul the spark plug and cause hard starting. Operation at an altitude that differs from that at which this engine was certified, for extended periods of time, may increase emissions.
  • Page 69: Emission Control System Information

    TECHNICAL & CONSUMER INFORMATION Emission Control System Information Source of Emissions The combustion process produces carbon monoxide, oxides of nitrogen, and hydrocarbons. Control of hydrocarbons and oxides of nitrogen is very important because, under certain conditions, they react to form photochemical smog when subjected to sunlight. Carbon monoxide does not react in the same way, but it is toxic.
  • Page 70 TECHNICAL & CONSUMER INFORMATION Problems That May Affect Emissions If you are aware of any of the following symptoms, have your engine inspected and repaired by your authorized Honda servicing dealer. Hard starting or stalling after starting. Rough idle. Misfiring or backfiring under load. Afterburning (backfiring).
  • Page 71: Air Index

    TECHNICAL & CONSUMER INFORMATION Air Index (Models certified for sale in California) An Air Index Information label is applied to engines certified to an emission durability time period in accordance with the requirements of the California Air Resources Board. The bar graph is intended to provide you, our customer, the ability to compare the emissions performance of available engines.
  • Page 72: Specifications

    TECHNICAL & CONSUMER INFORMATION Specifications Dimensions Model EU1000i Description code EZGA Length 17.8 in (451 mm) Width 9.5 in (242 mm) Height 14.9 in (379 mm) Dry mass [weight] 29 lbs (13 kg) Engine Model GXH50 Engine type 4-stroke, overhead valve, single cylinder Displacement 3.01 cu-in (49.4 cm ) Bore...
  • Page 73: Wiring Diagram

    TECHNICAL & CONSUMER INFORMATION Wiring Diagram...
  • Page 74: Consumer Information

    Parts Catalog This manual provides complete, illustrated parts lists. Available through your Honda dealer. Accessories Catalog Your authorized Honda power equipment dealer offers a wide selection of accessories (optional equipment) to make your generator even more useful. Visit www.hondapowerequipment.com/products/accessories/ and click on Generators and Welders to see the entire catalog of...
  • Page 75: Customer Service Information

    TECHNICAL & CONSUMER INFORMATION Customer Service Information Honda Power Equipment dealership personnel are trained professionals. They should be able to answer any question you may have. If you encounter a problem that your dealer does not solve to your satisfaction, please discuss it with the dealership’s management.
  • Page 76: Distributor's Limited Warranty

    To Obtain Warranty Service: You must take the Honda generator and proof of original retail purchase date, at your expense, to any Honda Power Equipment dealer in the United States, Puerto Rico, or the U.S. Virgin Islands who is authorized to service that product, during the dealer’s normal business hours.
  • Page 77: Emission Control System Warranty

    Emission Control System Warranty Your new Honda Power Equipment engine complies with the U.S. EPA, Environment Canada, and State of California emission regulations (models certified for sale in California only). American Honda Motor Co., Inc.
  • Page 78 You are responsible for presenting your power equipment engine to a Honda Power Equipment dealer as soon as a problem exists. The emission related warranty repairs should be completed in a reasonable amount of time, not to exceed 30 days.
  • Page 79 @ahm.honda.com Warranty Coverage: Honda power equipment engines sold in the United States and Canada are covered by this warranty for a period of two years from the date of delivery to the original retail purchaser or the length of the Honda Distributor’s Limited Warranty , whichever is longer.
  • Page 80 TECHNICAL & CONSUMER INFORMATION To Obtain Warranty Service: You must, at your own expense, take your Honda Power Equipment engine or the product on which it is installed, along with your sales registration card or other proof of original purchase date, to any Honda Power Equipment dealer who is authorized by Honda to sell and service that Honda product during his normal business hours.
  • Page 81 TECHNICAL & CONSUMER INFORMATION Disclaimer of Consequential Damage and Limitation of Implied Warranties: American Honda Motor Co., Inc. and Honda Canada Inc. disclaim any responsibility for incidental or consequential damages such as loss of time or the use of the power equipment, or any commercial loss due to the failure of the equipment;...
  • Page 82: Initial Use Instructions

    INITIAL USE INSTRUCTIONS ENGINE OIL The generator is shipped WITHOUT OIL in the engine. Place the generator on a level surface. Loosen the cover screw and remove the maintenance cover. COVER SCREW MAINTENANCE COVER With the generator in a level position, remove the oil filler cap/ dipstick.
  • Page 83: Fuel

    INITIAL USE INSTRUCTIONS FUEL Add fuel to the generator in a well-ventilated area. Never refuel the engine inside a building where gasoline fumes may reach flames or sparks. Keep gasoline away from appliance pilot lights, barbecues, electric appliances, power tools, etc. Spilled fuel is not only a fire hazard, it causes environmental damage.
  • Page 84 INITIAL USE INSTRUCTIONS Remove the fuel tank cap. FUEL TANK CAP Fuel carefully to avoid spilling fuel. Do not fill the fuel tank above the UPPER LIMIT MARK upper limit mark on the fuel strainer. Fuel can damage paint and plastic. Be careful not to spill fuel when filling your fuel tank.
  • Page 85: Before Operation

    INITIAL USE INSTRUCTIONS Move the generator at least 10 feet (3 meters) away from the fueling source and site before starting the engine. After initial fueling (or anytime the generator is run completely out of fuel), starting the engine may require additional pulls of the starter grip.
  • Page 86: Index

    INDEX AC Applications ..................29 AC OPERATION ..................27 AC PARALLEL OPERATION ..............30 AC Parallel Operation Applications ........... . 32 AIR CLEANER SERVICE ............... 49 Air Index ....................69 ARE YOU READY TO GET STARTED? ..........
  • Page 87 INDEX Eco-Throttle Switch ................15 ECO-THROTTLE SYSTEM ..............37 Electric Shock Hazards ................. Emission Control System Information ..........67 Emission Control System Warranty ........... 75 ENGINE LACKS POWER ..............63 Engine Oil ..................59, 80 ENGINE OIL CHANGE .................
  • Page 88 INDEX MAINTENANCE SAFETY ..............41 MAINTENANCE SCHEDULE .............. . 42 NO POWER AT THE AC RECEPTACLES ..........64 NO POWER AT THE DC RECEPTACLE ..........64 Oil Alert Indicator ................. 18 OPERATION ..................21 Operator Responsibility ...............
  • Page 89 INDEX SAFE OPERATING PRECAUTIONS ........... . 21 SAFETY LABEL LOCATIONS ..............Safety Precautions ................41 Serial Number Location ..............64 SERVICING YOUR GENERATOR ............40 SPARK ARRESTER SERVICE .............. . 53 SPARK PLUG SERVICE ............... . 51 Special Requirements ................
  • Page 90 MEMO...
  • Page 91: Quick Reference Information

    QUICK REFERENCE INFORMATION Fuel Type Regular unleaded gasoline with a pump octane rating of 86 or higher Engine Oil Type SAE 10W-30, API SJ or later (or equivalent), for general use (page 48) Spark Plug Type NGK: LR4C-E Electrode Gap 0.024 0.028 in (0.6 0.7 mm) Maintenance Before each...

Table of Contents