SERVICING YOUR GENERATOR

SEDIMENT CUP CLEANING

1.
Turn the fuel valve lever to the OFF position and remove the key.
2.
Remove the sediment cup by turning it counterclockwise.
3.
Wash the sediment cup in nonflammable solvent, and dry it
thoroughly.
4.
Reinstall the new O-ring and sediment cup.
5.
Turn the fuel valve ON and check for leaks.
50
ON
Gasoline is highly flammable and
explosive.
You can be burned or seriously
injured when handling fuel.
Stop the engine and keep heat,
sparks, and flame away.
Handle fuel only outdoors.
Wipe up spills immediately.
OFF
FUEL VALVE LEVER
KEY
O-RING
(replace)
SEDIMENT CUP