Pull starting:
1. Make sure that the
AC
circuit breaker is in the
OFF
position. The
generator may be hard to start if
a
load is connected.
2. Turn the fuel valve lever to the ON position.
3. Pull the choke knob to the CLOSED position. (with a cold and warm
engine)
4. Make sure the auto-throttle switch is in the OFF position, or more
time will be required for warm up.
5. Turn the engine switch to the
ON position.
6. Pull the recoil starter grip slowly until the resistance is felt, then pull
briskly.
7. Push the choke knob to the OPEN position as the engine warms up.
8. If you wish to use the auto-throttle system, turn the auto-throttle
switch to the ON position after the engine has warmed up for 2 or 3
minutes.
34