Diagnostic sequence – Stage 8
If the restart is successful the 20M LED goes off, the 60 minute timer LED (60M) comes on. The 60M LED will
remains on for 60 minutes from restart. A lighted 60M LED indicates the ice machine has experienced an over-
torque condition. If the ice machine runs without problems for 60 minutes and no additional torque errors occur,
the 60M LED goes off and the ice machine continues normal operation.
GREEN/YELLOW
BROWN
BLUE
BLACK
ORANGE
ORANGE
BLACK
Diagnostic sequence – Stage 9
The second error (2ND) LED comes on if an over-torque condition occurs while the 60M LED is still lit. The 2ND
LED indicates two consecutive over-torque situations have occurred. The ice machine will be shut down at this
time and will not restart unless the manual reset button is depressed.
GREEN/YELLOW
BROWN
BLUE
BLACK
ORANGE
ORANGE
BLACK
12CI400A • 12HI400A 220 V 60 Hz/230 V 50 Hz Dispensers
WHITE
BLACK
WHITE
RED
RED
BLACK
BLACK
YELLOW
WHITE
BLACK
WHITE
RED
RED
BLACK
BLACK
YELLOW
BLACK
BLACK
BLACK