Normal operation – Stage 2
The water sensor verifi es water in the fl oat reservoir. The water OK LED (WTR) comes on. At the same time, the
gearmotor, compressor and condenser fan motor come on, lighting the drive LED (DR) and compressor LED (C).
The gearmotor is started through a current style relay that is pulled in by the initial high current draw of the run
winding. The compressor is started with the start winding being energized through the normally closed contacts of
the potential relay, starting capacitor, and the run capacitor. The PWR, BE and WTR LED remain on.
GREEN/YELLOW
BROWN
BLUE
BLACK
ORANGE
ORANGE
BLACK
Normal operation – Stage 3
After the initial high current draw drops off, the gearmotor start relay contacts open, dropping out the start winding.
As the compressor comes up to normal running speed, the compressor start relay contacts open and the starting
capacitor drops out. The start winding remains energized through the run capacitor. The ice machine is now in a
normal icemaking mode. The ice machine will begin to produce ice and continue to produce ice until the bin level
control in the ice dispenser is satisfi ed. The PWR, B-E, DR, C and WTR LEDs are all on.
GREEN/YELLOW
BROWN
BLUE
BLACK
ORANGE
ORANGE
BLACK
18
WHITE
BLACK
WHITE
RED
RED
BLACK
BLACK
YELLOW
WHITE
BLACK
WHITE
RED
RED
BLACK
BLACK
YELLOW
BLACK
BLACK
12CI400A • 12HI400A 220 V 60 Hz/230 V 50 Hz Dispensers
BLACK
BLACK

Advertisement

Table of Contents
loading

This manual is also suitable for:

12ci400a-l12ci400a-s12hi400a-s

Table of Contents