Looping an External reference through the SE-3000

The SE-3000's built in TBCs can synchronise the input channels internally without the need for
external genlock. However, you can choose to loop an external reference through the SE-3000 if
you wish using the REF IN and REF LOOP (OUT) BNC connections provided on the rear of the
Main unit.
Once the BNC connections have been made and the external reference is supplied follow the instructions
below.
Press the SETUP button in the Menus button group on the Control Panel / Keyboard.
Tap on Genlock in the Yellow menu list and the screen options below will be shown.
Tap on Analog Ref to select it as the Genlock Source and tap below Enable to show On.
Alternatively an Input from 1 to 8 could be chosen as the reference source instead.
Now look at the Touch Screen Menu Panel.