3.
Time of Regeneration - This setting is used to program the time at which a regeneration is to
occur in the delay mode, or in immediate mode with time clock backup on. The display will first
show "tor" for two seconds.
After "tor" is shown the display will then show the default of 2:00 AM (or the current
programmed time of regeneration if already set). The time can be adjusted in 30 minute
increments by pressing the "Up" or "Down" keys.
Pressing the "Program" key will save the setting and move to the next programming step.
4.
Meter "K" Factor - This setting is used to set the "K" factor
(the number of pulces a flow device emits to repersent a
volume of water). Set the "K" factor to 80. Adjust
the valve with the "up" and "Down" keys.
Pressing the "Program" key will save the setting and move
to the next programming step.
5.
Cycle 1 Time - This setting is used to program the cycle
1 time that is backwash. The time of the cycle is kept in
minutes. The display will show the "BACKWASH" and
"MINS" icons and the cycle time in the right most digits.
Adjust the value with the "Up" or "Down" keys.
Pressing the "Program" key will save the setting and move
to the next programming step.
6.
Cycle 2 Time - This setting is used to set the time in
minutes for cycle 2. This cycle is brine draw / slow rinse
for softeners. The display will show the "BRINE RINSE"
and "MINS" icons and the cycle time in the right most
digits. Adjust the value with the "Up" or "Down" keys.
See attached capacity charts to set "brine draw / slow
rinse" times.
Pressing the "Program" key will save the setting and move
to the next programming step.
7.
Cycle 3 Time - This cycle is the Fast Rinse/Refill for
softeners. The display will show the "Fast Rinse/Refill"
and "Mins" icons and the cycle time in the far right digits.
See attached capacity charts to set "refill" time (round to
the nearest minute). Adjust the value with the "Up" and
"Down" keys.
Pressing the "Program" key will move to the next programming step.
8.
Total Capacity Set Point (Max Capacity) - This setting is used to program a value that
Time Flashing