Loading the Tank (12" and 14" Tanks)
1.
Position the tank so that the Culligan
2.
Remove the inlet strainer.
3.
Install the outlet manifold into the tank (Figure 10).
4.
Cover the tops of the manifolds with a clean rag.
5.
Using a large-mouth funnel, load the Culligan underbedding through the top of the tank.
Caution! DO NOT allow the outlet manifold to move when loading the media. The
manifold must remain vertical to ensure a good seal at the gasket. Rap the tank near the
bottom with a rubber mallet to level the sand.
6.
Aqua-Sensor
®
Installation (optional
device)
A. Measure the sensor cable length
as shown in Figure 10 and Table 1
(the Aqua-Sensor cord is set at the
factory for a 9" tank).
B.
Loosen the small Aqua-Sensor Plug,
a needle-nose pliers works best.
C. Moisten the cable sheath and slide
the cable grip up or down to the
proper cable length.
D. Tighten the small Aqua-Sensor plug
so that the fitting cannot slide along
the cable.
Note: There must be no kinks or bends in
the cable.
Figure 10
®
logo is in the front.
Dimension "X" is the exposed length the Aqua-
cord (cord length from the Aqua-Sensor
Sensor
®
plug to the circuit board connector). You can then
verify the Aqua-Sensor probe is inserted to the
proper depth by confirming dimension "X" is at
the corrected length.
Tank Model
9" Quadra-Hull
10" Quadra-Hull Tank
12" Quadra-Hull Tank
14" Quadra-Hull Tank
Table 1
E.
Insert the probe and cable through the Aqua-Sensor port.
7.
Load the tank with the Cullex
not required.
8.
For Total Home Advanced units, load the carbon media per
the a mount in the specifications. Leveling is not required.
Figure 11
X
Tank
34 1/2"
30 1/2"
32 1/2"
22 1/2"
®
ion exchange resin. Leveling is
9. Remove the funnel.
10. Install the inlet
strainer making sure
Small
to thread the strainer
Aqua-Sensor
®
until it bottoms out
Plug
on the tank thread.
Failure to install the
strainer correctly can
cause the control to
leak.
Y
40"
44"
42"
52"