4.
Installing the titanium apatite
photocatalytic air-purifying filter
and deodorizing filter for streamer.
1) Open the front panel to pull out the air filter.
2) Attach the
purifying filter.
3) Attach the
4) Replace the air filter to its original position and close
the front panel.
5.
How to replace the drain plug and
drain hose.
• Replacing onto the left side
1) Remove the insulation fixing screws on the right to
remove the drain hose.
2) Reattach the insulation fixing screw on the right as it was.
*(Forgetting to attach this may cause water leakages.)
3) Remove the drain plug on the left side and attach it to
the right side.
4) Insert the drain hose and tighten with included
indoor unit fixing screw.
D
6.
How to set the different addresses.
• When 2 indoor units are installed in 1 room, the
2 wireless remote controllers can be set for different
addresses.
1) Remove the front grille. (3 screws)
2) Cut the address jumper "JA". (See Fig. 1)
3) Remove the remote controller lid and cut the
address jumper "J4". (See Fig. 2)
Room Air Conditioners H-Series
titanium apatite photocatalytic air-
C
deodorizing filter for streamer.
B
Left side
Titanium apatite
C
photocatalytic
air-purifying filter
Drain hose attachment position
* The drain hose is on the back of the unit.
Left side
Front side of unit
Attachment on the left side
Indoor unit
D
fixing screw
Drain hose
How to set drain plug.
Insert a hexagon wrench (3/16 inch (4mm)).
Fig. 1
Cut JA.
Fig. 2
Cut section
Installation Manual
Right side
B
Deodorizing filter
for streamer
Right side
Attachment on the right side (factory default)
Insulation
fixing screw
Drain hose
Do not apply lubricating
oil (refrigerant oil) when
inserting.
Application of causes
deterioration and drain
leakage of the plug.
Electric parts box cover