Piping Diagrams - Daikin Quaternity H-Series Engineeiring Data

H-series split-system room air conditioners
Table of Contents

Advertisement

Piping Diagrams

6. Piping Diagrams
FTXG09/12/15HVJU
INDOOR UNIT
FIELD PIPING
1/ 4(6.4)CuT
SINGLE UNION JOINT
FIELD PIPING
3/8(9.5)CuT
SINGLE UNION JOINT
RXG09/12/15HVJU
OUTDOOR UNIT
5/16
HEAT EXCHANGER
(7.9)CuT
5/16
(7.9)CuT
HEAT
EXCHANGER
THERMISTOR
AUXILIARY
HEAT EXCHANGER
FAN MOTOR
PROPELLER FAN
MUFFLER
8
HEAT EXCHANGER
THERMISTOR
SOLENOID VALVE
ON HEAT EXCH.
AT RATED VOLTAGE: CLOSED
(UNDER DEHUMIDIFICATION
OPERATION)
CROSS FLOW FAN
HEAT EXCHANGER
M
FAN MOTOR
3/8(9.5)CuT
REFRIGERANT FLOW
COOLING
HEATING
9/32(7.0)CuT
9/32(7.0)
MUFFLER
CuT
WITH
FILTER
9/32(7.0)CuT
1/4(6.4)CuT
1/4
(6.4)CuT
M
1/2(12.7)CuT
1/2(12.7)CuT
FOUR WAY VALVE
ON : HEATING
DISCHARGE PIPE
THERMISTOR
COMPRESSOR
1/2(12.7)CuT
4D061001
OUTDOOR TEMPERATURE
THERMISTOR
MOTOR
OPERATED
1/4
VALVE
(6.4)CuT
FILTER
FILTER
MUFFLER
LIQUID STOP
VALVE
MUFFLER
3/8(9.5)CuT
GAS STOP
VALVE
EDUS04-906_b
FIELD PIPING
(1/4(6.4)CuT)
REFRIGERANT FLOW
COOLING
FIELD PIPING
(3/8(9.5)CuT)
HEATING
UNIT=INCH(mm)
3D062171A
Room Air Conditioners H-Series