244
Chapter 19—Other Functions

Calibrating the Faders

The 01V96 motorized fader positions may shift over time depending on the operating con-
ditions and environment. You can correct the shifted faders using the Calibration function.
1 Make sure that the power to the 01V96 is turned off.
2 Press and hold down the [ENTER] button, then turn on the POWER ON/OFF
switch.
After a while, the following calibration window appears.
3 Make sure that "1 FADER MOVE & FADER POSITION" is selected, then press
[ENTER].
To adjust only the motor fader movement, use the cursor buttons to select "2 FADER
MOVE ONLY," then press [ENTER].
To adjust only the fader position, use the cursor buttons to select "3 FADER POSITION
ONLY," then press [ENTER]. Proceed to Step 5.
To cancel the calibration operation, use the cursor buttons to select "4 QUIT," then press
[ENTER]. The 01V96 starts in normal mode.
4 The calibration operation begins, adjusting the motor fader movement, and
the 01V96 displays a message that indicates the calibration operation is in
progress.
The calibration operation takes about two minutes. DO NOT touch the faders during the
operation.
01V96 Version 2—Owner's Manual