CHECKING THE BATTERY AND THE SYSTEM VERSION

The Utility | Battery page enables you to check the
condition of the internal memory-backup battery and
the system version number. To locate this page, press
the DISPLAY ACCESS [UTILITY] button repeatedly.
q Status
If the Status is "Okay," the battery has sufficient voltage
for operation. If the Status is "Voltage Low!," failure to
replace a low battery may result in data loss.
w Ver X.XX (X.XX represents the version number.)
This indicator identifies the system version number.
Check the current system version number before you
update the system software.

CALIBRATING THE FADERS

The 01V96 motorized fader positions may shift over time
depending on the operating conditions and environment.
You can correct the shifted faders using the Calibration
function.
1 Make sure that the power to the 01V96 is turned off.
2 While holding down the [ENTER] button, turn on the
POWER ON/OFF switch.
After a moment, the 01V96 displays a message
indicating that the calibration is in progress.
Calibration takes about two minutes. It is important that
you do not touch the faders while this message is
displayed.
When calibration is finished, the 01V96 displays a page
that enables you to fine-tune the fader position.
3 Follow the instructions on the display and lower all
faders to –
, then press [ENTER].
4 Set faders 1–16 to –15 and the Stereo fader to –30,
then press [ENTER].
5 Set faders 1–16 to 0, then press [ENTER].
Proceed to the next step without moving the Stereo fader
this time.
6 Finally, set faders 1–16 to +10 and the Stereo fader
to 0, then press [ENTER].
This is the end of the fader calibration process. The
01V96 restarts in normal mode.
q
w
01V96
119