Jig Connections; Environment Setup - FujiFilm FinePixS5000 Service Manual

Digital camera
Table of Contents

Advertisement

FinePix S5000 Service Manual

4-4. Jig Connections

* Always measure input voltage close to the DC_IN pin when making adjustments.

4-5. Environment Setup

(1)Setup for camera adjustment (Fig.A)
<<All white pattern>>
Set the distance between the camera reference face (*1)
and the pattern box to within approximately 50mm.
Filter (LB140) and reference face in direct contact.
1. Color temperature: 6100±50K (with LB140 filter)
Measurement position : middle of pattern box
Measuring device : Minolta Color Meter III F or equiva-
lent
*Color temperature measurement
Filter (LB140) and pattern box in direct contact
Adjust color temperature of pattern box to 6100±50K
with filter (LB140) in contact with color thermometer.
2. Luminance: 160±5cd/m
Measurement position : middle of pattern box
Measuring device : Minolta Luminance Meter LS-110 or
equivalent
*Luminance measurement
Filter (LB140) and pattern box in direct contact
USB CABLE
POWER CABLE JIG
(with LB140 filter)
2
4. Adjustments
To PCI-2746C Board
VIDEO ADJ. JIG
TV MONITOR
Within 80mm
Within
30mm
Filter (LB140)
Camera
<Fig.A> Setup for Camera Adjustment
(*1)Front face of LENS ASSY used as camera reference face.
AC-100-240V
Within
50mm
Center
Pattern box
37

Hide quick links: