CAUTION
• Do not touch the switch with wet fingers. Touching a
switch with wet fingers can cause electric shock.
• Do not allow children to play on or around the unit to
prevent injury.
• Be careful when transporting the product.
• Do not install the unit in the following locations:
(a) Where a mineral oil mist or oil spray or vapor is pro-
duced, for example, in a kitchen.
Plastic parts may deteriorate and fall off or result in
water leakage.
(b) Where corrosive gas, such as sulfurous acid gas, is
produced.
Corroding copper pipes or soldered parts may result
in damage.
(c) Near machinery emitting electromagnetic waves.
Electromagnetic waves may disturb the operation of
the control system and cause the unit to malfunction.
(d) Where flammable gas may leak, where there is car-
bon fiber or ignitable dust suspension in the air, or
where volatile flammables such as thinner or gaso-
line are handled. Operating the unit in such condi-
tions can cause a fire.
• Do not allow exhaust air to enter the outdoor air intake
vent.
This may cause the air of the room to become contami-
nated, harming the health.
NOTE
• Install the power supply and control wires for the unit at
least 3.3 feet away from televisions or radios to prevent
image interference or noise. Depending on the radio
waves, a distance of 3.3 feet may not be sufficient to
eliminate the noise.
• Dismantling the unit and additional parts must be done
in accordance with the relevant local, state and national
regulations.
• This unit is an appliance that should not be accessible
to the general public.
• Insulate the two outdoor ducts and the supply air duct
to prevent condensation.
If this is not done completely, water may enter the build-
ing, may damage furniture, etc.
• In areas where insects are easily attracted to a light,
such as where there is a window or light near a ventila-
tion opening, extremely small insects can sometimes
infiltrate the room by passing through the ventilation
opening.
Since totally preventing against infiltration by extremely
small insects is difficult, it is important to consider a
serious solution like a filter box (field supply) during the
design process to protect against insect infiltration.
English
VAM-GVJU
2.

BEFORE INSTALLATION

The accessories needed for installation must be retained
in your custody until the installation work is completed. Do
not discard them!
1. Decide upon a line of transport.
2. Leave the unit inside its packaging while moving, until
reaching the installation site. Where unpacking is unavoid-
able, use a sling of soft material or protective plates
together with a rope when lifting, to avoid damage or
scratches to the unit.
Hold the unit by the hanger brackets (4) when opening the
crate and moving it, and do not lift it holding on to any
other part (especially the duct connecting flange).
2-1 PRECAUTIONS
• Be sure to instruct customers how to properly operate the
unit (especially maintenance of air filter, and operation pro-
cedure) by having them carry out operations themselves
while looking at the manual.
• Where the air contains high levels of salt such as that near
the ocean and where voltage fluctuates greatly such as that
in factories. Also in vehicles or vessels.
2-2 DIMENSIONS
• See figure 1 (All dimensions are in inches.)
1. Service space for the heat exchanger cores, the air filters,
control box and fans
2. Service cover
3. Inspection hatch ( 18 in.)
4. Control box
5. Hanger bracket (7/16×1-9/16 in. oval hole)
6. Exhaust fan
7. OA (Outdoor air) Outdoor air from outside
8. EA (Exhaust air) Exhaust air to outside
9. Supply air fan
10. SA (Supply air) Supply air to inside
11. RA (Return air) Return air from inside
12. Damper
13. Heat exchanger core
14. Air filters
15. Duct connecting flange
Model name
Weight (LBS) Applicable nominal diameter of duct
VAM300GVJU
71
VAM470GVJU
121
VAM600GVJU
148
VAM1200GVJU
346
2-3 ACCESSORIES
Check the following accessories are included with your unit.
M4 tapping screw
Duct connecting
Name
(For connecting
flange
duct)
Quantity
4 pcs.
Refer to Table 1
Shape
Insulation
Name
Clamp
tube
Quantity
5 pcs.
1 pc.
Shape
Installation Manual
[in.]
φ 8
φ 10
φ 10
φ 14
Wire harness for
external damper
operation
1 pc.
(Other)
• Installation manual
• Operation manual
2
3P034928-7Q
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vam300gvjuVam470gvjuVam600gvjuVam1200gvju

Table of Contents