ADJUSTING FOR BEVEL CUTS
Disconnect tool from power source!
1. Raise the bevel-adjustment
locking lever (A) Fig. 5.
2. Tilt the saw base until the desired
graduation line on the bevel
segment (B) Fig. 5 aligns with the
indicating mark (C) Fig. 5 on the
bracket.
3. Return the bevel-adjustment
locking lever to the locked
position and press it down firmly.
90° and 45° BEVEL POSITIVE STOPS
This saw is equipped with adjustable
positive stops for both 90° cuts (A)
Fig. 6 and 45° bevel cuts (B) Fig. 6.
These stops have been set at the
factory. However, check them
occasionally to ensure accuracy.
TO ADJUST 90° POSITIVE STOP
Disconnect tool from power source!
1.
Raise the bevel-adjustment locking lever (A) Fig. 5, and position the
base for 90° cuts Make sure that the top of the base is in contact with
the bottom of the stop screw (A)
Fig. 6, and tighten the locking
lever.
2.
Turn the saw upside down,
retract the telescoping guard,
and see if the blade is 90° to the
base (Fig. 7).
3.
To adjust, loosen the bevel -
adjustment locking lever. Keep
the top of the base in contact
with the stop screw. Turn the
stop screw until the blade is 90°
to the base.
A
Fig. 6
Fig. 7