Sharp AL-1651CS Service Manual page 82

Digital multifunctional system
Hide thumbs Also See for AL-1651CS:
Table of Contents

Advertisement

Main
Sub
Contents
code
code
26
30
CE mark support control ON/
OFF (CE MARK)
38
Cancel of stop at drum life
over (DRUM LIFE END)
39
Memory capacity check
(MEM.CHK)
40
Polygon motor OFF time
setting (Time required from
completion of printing to
turning OFF the motor) (LSU
MOTOR OFF)
42
Transfer ON/OFF timing
control setting (TC ON
TIMING)
[Function]
When this test command is executed, the current set CE mark support control is displayed. Enter the
code number corresponding to the desired CE mark support control and press [ENTER/START] key
to save the setting.
Code number
Setting
0
CE mark support control OFF
1
CE mark support control ON
[Operation]
The operation is similar to test command 21-01.
[Function]
When this test command is executed, the current setting is displayed. Enter the code number corre-
sponding to the desired setting and press [ENTER/START] key to save the setting.
Code number
0
Stop at drum life over
1
Cancel of stop at drum life over
[Operation]
The operation is similar to test command 21-01.
[Function]
When the test command is executed, the currently installed SDRAM of the main unit is displayed.
Code number
Setting
8
8 MBYTE
[Operation]
1) Memory capacity display
26-39 MEM.CHK
8 MBYTE
[Function]
When this test command is executed, the current setting is displayed. Enter the code number corre-
sponding to the desired setting and press [ENTER/START] key to save the setting.
Code number
Setting
0
0sec
1
30sec
2
60sec
3
90sec
[Operation]
The operation is similar to test command 21-01.
[Function]
When this test command is executed, the currently set value of the transfer ON timing is displayed
(initial display), and the set value is saved. (Setting range: 0 – 9, Default: 5)
Code
Setting
0
0 msec
1
40 msec
2
–30 msec
3
–20 msec
4
–10 msec
5
0 msec
6
+10 msec
7
+20 msec
8
+30 msec
9
+40 msec
The default "5" of transfer ON timing is "330ms passed from PS release."
When set to "0," it is the same as setting to "5."
[Operation]
The operation is similar to test command 21-01.
AL-1651CS TEST COMMAND, TROUBLE CODES 10 - 12
Details of function/operation
Display item
OFF
ON
Setting
STOP
NONSTOP
Remark
Display item
0 SEC.
30 SEC.
60 SEC.
90 SEC.
Remark
Default
Remark
Default (100V series)
Display item
Remark
Default
Remark
Default

Advertisement

Table of Contents
loading

Table of Contents