code
code
24
14
SPF JAM total counter clear
(S JAM TTL CLR.)
15
Scanner mode counter clear
(S-MODE CLR.)
25
01
Main motor operation check
(MAIN MOTOR CHK)
10
Polygon motor operation
check (LSU CHK)
26
01
Manual feed setting
(BYPASS)
02
(R)SPF setting (SPF/RSPF)
[Function]
When [ENTER/START] key is pressed, the SPF JAM total counter value is cleared to 0, and
"000,000" is displayed on the LCD.
[Operation]
1) Initial display
24-14 S JAM TTL CLR.
CLEARED
000,000
[Function]
When [ENTER/START] key is pressed, the scanner mode counter value is cleared to 0, and
"000,000" is displayed on the LCD.
[Operation]
1) Initial display
24-15 S-MODE CLR.
CLEARED
000,000
[Function]
When [ENTER/START] key is pressed, the main motor (and the duplex motor in the case of a duplex
model) is operated for 30sec.
To reduce toner consumption, if the developing unit is installed, the developing bias, the main
charger, and the grid are also outputted.
In this case, laser discharge is required when stopping the motor, the polygon motor is also operated
at the same time. Check for installation of the developing unit. If it is not installed, the high voltage
above is not outputted and only the motor is rotated.
To check the developing bias, install the developing unit.
After completion of 30sec operation, the machine goes into the sub code entry standby mode.
[Operation]
1) Initial display
25-01 MAIN MOTOR CHK
EXECUTING...
[Function]
When [ENTER/START] key is pressed, the Bios is called to rotate the polygon motor for 30sec.
After completion of 30sec operation, the operation is turned off with the Bios and the machine goes
into the sub code entry standby mode.
[Operation]
1) Initial display
25-10 LSU CHK
EXECUTING...
[Function]
When the test command is executed, the current set bypass is displayed.
Enter the code number corresponding to the bypass and press [ENTER/START] key to save the set-
ting.
Code number
Bypass
0
Single bypass
1
Multi bypass
For single bypass, there is no schedule for production.
[Operation]
The operation is similar to test command 21-01.
[Function]
When this test command is executed, the current set SPF is displayed. Enter the code number corre-
sponding to the desired SPF and press [ENTER/START] key to save the setting.
Code number
SPF
0
SPF NO
1
SPF YES
2
RSPF YES
[Operation]
The operation is similar to test command 21-01.
AL-1651CS TEST COMMAND, TROUBLE CODES 10 - 10
Details of function/operation
Display item
SINGLE
MULTI
Display item
SPF OFF
SPF ON
RSPF ON