Hobart 1435 Owner's Manual page 33

Engine driven welding generator
Table of Contents

Advertisement

C. Engine
Trouble
Engine will not crank (Honda electric-
start models only).
Engine will not start.
Engine stopped during normal
operation.
Battery discharges between uses (elec-
tric-start models only).
Unstable or sluggish engine speeds.
Reset ignition circuit breaker (see Section 7-3).
Check battery voltage.
Check battery connections and tighten if necessary.
Have Factory Authorized Service Agent check engine ignition circuit.
Check fuel level (see Section 4-4 or 4-5).
Move choke lever to correct position (see Section 5-1 or 5-2).
Open fuel valve (see Section 4-4 or 4-5). Close fuel valve before moving unit or carburetor may flood and
make starting difficult.
Check battery voltage (Honda electric-start models only).
Check battery connections and tighten if necessary (Honda electric-start models only).
Check oil level (see Section 4-4 or 4-5). Engine stops if oil level is too low. Refill crankcase with proper
viscosity oil for operating temperature.
Have Factory Authorized Service Agent check low oil level shutdown switch.
Check fuel level (see Section 4-4 or 4-5).
Open fuel valve (see Section 4-4 or 4-5). Close fuel valve before moving unit or carburetor may flood and
make starting difficult.
Check oil level (see Section 4-4 or 4-5). Engine stops if oil level is too low.
Clean battery, terminals, and posts with baking soda and water solution; rinse with clear water.
Periodically recharge battery (approximately every 3 months).
Replace battery.
Check voltage regulator and connections according to engine manual.
Check engine speed, and adjust if necessary (see Section 7-4 or 7-5).
Check throttle/governor linkage for smooth, non-binding operation.
Tune-up engine according to engine manual.
Remedy
OM-498 Page 29