8-5-2. Operation panel DIP switches (KE-436B, 436C)
Note:
Always turn off the power before setting the DIP switches.
DIP switch A
Switch
DIPA-1
DIPA-2
DIPA-3
DIPA-4
DIPA-5
DIPA-6
DIPA-7
DIPA-8
DIP switch B
Switch
DIPB-1
DIPB-2
DIPB-3
DIPB-4
DIPB-5
DIPB-6
DIPB-7
DIPB-8
Work clamp does not automatically lift after
sewing is completed.
Pedal mode is switched.
-
-
After sewing is completed, work clamp does not automatically rise. (only in split
mode)
Clamping force output is produced. (Inner clamping device available as an option)
-
Thread breakage detector device is activated (available as an option).
Single split mode activated
-
Thread is not trimmed after an emergency stop.
Needle cooler output is produced. (Needle cooler available as an option)
When a rotating-type thread breakage detector device is used, detection precision
is increased from 8 to 14.
When a fiber-type thread breakage detector device is used, detection precision is
increased from 5 to 10.
Fiber-type thread breakage detector device is ON, and DIP switch A-8 is ON
(available as an option).
-
-
KE-430B, 430C series
All DIP switches are set to OFF at the time of
shipment.
Motion when set to ON
See "8-8. Setting the work
clamp mode"
Motion when set to ON
8. ELECTRIC MECHANISM
1086Q
148