Siemens 340 Manual page 68

Load feeders and motor starters
Table of Contents

Advertisement

Configuration
4.6 Examples/applications
Basic configuration
...
Figure 4-2
Configuration with 3SK1 safety relay and device connectors
If you use safety-related motor starters (3RM11..-.AA04 / 3RM13..-.AA04) with a control
supply voltage of 24 V DC with the 3SK1 safety relay, you can establish safe connection of
the safety-related wiring using the device connectors. Use of device connectors avoids
errors when setting up the control circuit wiring and offers savings in cable laying. In addition,
the test overhead following completion of the control cabinets is reduced. The
3RM11/3RM13 safety-related motor starters can be used optimally as output expansions in
the 3SK1 system.
68
Instead of the black box, one of the modules
SIRIUS 3TK28 safety relay
SIRIUS 3SK1 safety relay
SIMATIC S7 fail-safe modules
SIRIUS 3RK3 modular safety system
SIRIUS 3RM11 Failsafe or SIRIUS 3RM13 Failsafe safety-related motor starter
SIRIUS 3RV2 motor starter protector
EMERGENCY-STOP button
Motor
Basic configuration with safety relay or safety-related controller
...
can be used
SIRIUS 3RM1 motor starter