Failure of the safety function during hybrid operation of Failsafe and Standard motor
starters
Hybrid operation of 3RM10/3RM12 Standard motor starters with 3RM11/3RM13 Failsafe
motor starters in safety-related applications is not admissible.
Only ever use safety-related motor starters (3RM11 Failsafe and 3RM13 Failsafe) in safety-
related applications.
Note
SILCL 3 to EN 62061:2005, PL e/Cat. 4 to EN ISO 13849-1:2008
The 3RM11 Failsafe and 3RM13 Failsafe safety-related motor starters are designed in such
a way as to allow implementation of safety-related applications up to SILCL 3 in accordance
with EN 62061 and PL e/Cat. 4 in accordance with EN ISO 13849-1.
Note
Use of PELV/SELV power supply units
Power to the 3RM11 Failsafe and 3RM13 Failsafe safety-related motor starters must be
supplied from PELV/SELV power supply units.
2.4

Intended use

Hazardous Voltage.
Can Cause Death, Serious Injury, or Property Damage.
Proper use of hardware products
This equipment is only allowed to be used for the applications described in the catalog and
in the technical description, and only in conjunction with non-Siemens equipment and
components recommended by Siemens.
Correct transport, storage, installation and assembly, as well as careful operation and
maintenance, are required to ensure that the product operates safely and without faults.
EU note: Commissioning is absolutely prohibited until it has been ensured that the machine
in which the component described here is to be installed complies with the stipulations of
the Directive 2006/42/EC.
SIRIUS 3RM1 motor starter
Manual, 11/2013, A5E0345285095020A/RS-AB/002
WARNING
WARNING
Product-specific safety information
2.4 Intended use