MHz SCAN

MHz Scan monitors a 1 MHz segment of the band, using the current frequency
step size. The current 1 MHz digit determines the limits of the scan. For
example, if the current frequency is 145.400 MHz, then the scan range would be
from 145.000 MHz to 145.995 MHz (the exact upper limit depends on the current
frequency step size).
1 Select your desired band.
2 Press [VFO].
3 Rotate the Tuning control to select a frequency within your desired 1 MHz
range.
4 Press and hold the Tuning control for 1 second to start scanning.
• Scan starts at the current frequency.
• The 1 MHz decimal blinks while scanning is in progress.
• To reverse the scan direction, turn the Tuning control clockwise (upward scan) or
counterclockwise (downward scan). You can also press microphone [UP]/ [DWN].
5 To quit MHz Scan, press the Tuning control again.

CALL SCAN

Use Call Scan to monitor both the Call channel and either the currently selected
VFO frequency or the currently selected Memory channel.
1 Select your desired VFO frequency or Memory channel.
2 Press [CALL] (1s) to start Call Scan.
• The 1 MHz decimal blinks while scanning is in progress.
• When scanning a Memory channel, the Call channel on the same band as the
selected Memory channel is used for scan.
3 To quit Call Scan, press [CALL] again.
Note: The Memory channel selected is scanned even if it has been locked out of scan.