Technical Data - Worcester GREENSTAR 30CDi Installation, Commissioning And Servicing Instructions

Greenstar cdi classic regular wall hung rsf gas fired condensing regular boiler, for open vented and sealed central heating systems and indirect domestic hot water
Table of Contents

Advertisement

APPLIANCE INFORMATION
2.2

TECHNICAL DATA

DESCRIPTION
Heating
Max. rated heat input
Max. rated heat output net 40/30°C
Max. rated heat output net 50/30°C
Max. rated heat output net 80/60°C
Min. rated heat output net 40/30°C
Min. rated heat output net 50/30°C
Min. rated heat output net 80/60°C
Min. rated heat input net
Max. flow temperature
Max. permissible operating pressure
Gas flow rate - Max. 10 minutes from lighting
Natural Gas G20
Propane Gas (LPG)
Flue
Flue Gas Temp. 80/60°C, rated min. load
Flue Gas Temp. 40/30°C, rated min. load
CO2 level at max. rated heat output
CO2 level at min. rated heat output
NOx - class
Condensate
Max. condensation rate
pH value, approx.
Electrical
Electrical power supply voltage
Frequency
Max. power consumption
General Data
SEDBUK
Appliance protection rating
Permissible ambient temperatures
Nominal capacity of appliance
Noise output level
Total boiler weight (lift weight)
Packaged boiler weight
SEDBUK 2005
SEDBUK 2009
Table 3 Technical data
6
NATURAL GAS
UNITS
30CDi
kW
30.9
kW
32.1
kW
31.8
kW
30.0
kW
8.6
kW
8.6
kW
7.7
kW
8.0
°C
nom.90
bar
3.0
m3/h
3.2
kg/h
-
°C
76/58
°C
55/33
%
9.6
%
9.0
5
I/h
2.7
4.8
AC...V
230
Hz
50
W
approx.70
band
A
IP
X4D
°C
0-50
I
3.5
dB(A)
43
kg
39.5
kg
48
%
90.3
%
89.
L.P.G
40CDi
30CDi
42.0
30.9
43.7
32.1
43.3
31.8
40.8
30.0
10.6
12.4
10.5
12.3
9.4
11.0
9.8
11.5
nom.90
nom.90
3.0
3.0
4.4
-
-
2.4
87/58
76/58
58/35
55/33
9.7
11.5
9.1
10.5
5
5
3.7
2.7
4.8
4.8
230
230
50
50
approx.100
approx.70
A
A
X4D
X4D
0-50
0-50
3.5
3.5
47
43
39.5
39.5
48
48
90.2
92.3
89.1
90.5
40CDi
42.0
43.7
43.3
40.8
15.7
15.5
13.9
14.5
nom.90
3.0
-
3.3
87/58
58/35
11.5
10.5
5
3.7
4.8
230
50
approx.100
A
X4D
0-50
3.5
47
39.5
48
92.0
90.2
6 720 806 548 (2013/02)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greenstar 40cdiGreenstar 40cdi

Table of Contents