Worcester GREENSTAR 30CDi Installation, Commissioning And Servicing Instructions page 38

Greenstar cdi classic regular wall hung rsf gas fired condensing regular boiler, for open vented and sealed central heating systems and indirect domestic hot water
Table of Contents

Advertisement

SERVICING AND SPARES
▶ Re-assemble with the new gasket and secure with the screws (F)
removed earlier.
13
Fig. 65 Electrode assembly
14. AIR/GAS MANIFOLD
WARNING: Air/Gas manifold
▶ Do not remove the manifold unless a new gasket is
available for re-assembly.
1. Remove cover panel (A) by removing screws (B).
▶ Check that the boiler is completely isolated from the gas supply.
1.
B
A
Fig. 66 Top panel
2. Remove clips (C) and unscrew the two bolts (D).
▶ Unscrew and remove the two hexagon screws (E) securing the fan.
▶ Slacken the rear securing bolt (F).
F
2.
Fig. 67 Release air/gas manifold
38
G
F
B
6720647361-63.1Wo
C
D
6720647361-64.1Wo
3. Remove air/gas manifold (I)
E
E
3.
Fig. 68 Air/gas manifold
4. Open air/gas manifold (I).
▶ Carefully withdraw diaphragm (J) from fan intake tube and check for
soiling and splits.
4.
I
I
Fig. 69 Diaphragm
15. BURNER
▶ Remove the burner (H).
▶ Replace new burner in correct position.
▶ Refer to section 6.1.5 "Re-assembly of the burner cover"
▶ Ensure that a new seal (K) is used, refer to fig. 69.
Fig. 70 Burner removal
16. HEAT EXCHANGER
▶ Isolate flow and return valves and drain the boiler.
▶ Remove condensate trap (see page 36).
▶ Remove fan assembly (see page 37).
G
H
J
K
H
6 720 806 548 (2013/02)