A&D UA-767PC Instruction Manual

A&D UA-767PC Instruction Manual

Digital blood pressure monitor
Hide thumbs Also See for UA-767PC:

Advertisement

Digital Blood Pressure Monitor
Model UA-767PC
Instruction Manual
Original
'
Manuel d
instructions
Traduction
Manual de Instrucciones
Traducción
Manuale di Istruzioni
Traduzione
Bedienungsanleitung
Übersetzung
Gebruiksaanwijzing
Vertaling
使用手冊
翻譯
1WMPD4002088B

Advertisement

Table of Contents
loading

Summary of Contents for A&D UA-767PC

  • Page 1 Digital Blood Pressure Monitor Model UA-767PC Instruction Manual Original ’ Manuel d instructions Traduction Manual de Instrucciones Traducción Manuale di Istruzioni Traduzione Bedienungsanleitung Übersetzung Gebruiksaanwijzing Vertaling 使用手冊 翻譯 1WMPD4002088B...
  • Page 2: Table Of Contents

    Contents Dear Customers .....................2 Preliminary Remarks ....................2 Precautions......................2 Parts Identification ....................4 Symbols........................5 Setting the Clock ....................6 Preparation for Measurements ................7 Installing / Changing the Batteries ...............7 Connecting the Air Hose ................7 Connecting the AC Adapter .................7 Selecting the Correct Cuff Size..............8 Applying the Arm Cuff ..................9 How to Take Proper Measurements ............9 Measurement ....................9...
  • Page 3: Dear Customers

    Dear Customers Congratulations on purchasing a state-of-the-art A&D blood pressure monitor, one of the most advanced monitors available today. Designed for ease of use and accuracy, this device will facilitate your daily blood pressure regimen. We recommend that you read through this manual carefully before using the device for the first time.
  • Page 4 Contraindications The following are precautions for proper use of the device. Do not apply the cuff to an arm with another medical electrical equipment attached. The equipment may not function properly. People who have a severe circulatory deficit in the arm must consult a doctor before using the device, to avoid medical problems.
  • Page 5: Parts Identification

    Parts Identification DC jack Data Port Systolic Display Air Socket Pressure Switch Measurement Diastolic Display in Progress Clock Button START Button Memory Access Indicator Pulse Display Low Battery Display Clock Display Air Hose Air Connector Plug Proper Fit range Index Mark Artery position mark Arm cuff...
  • Page 6: Symbols

    Symbols Symbols Function / Meaning Treatment Turns on or off the device Sets the clock / Does not store the current data Direction guide to install battery Direct current Serial number Date of manufacture Type BF: Device, cuff and tubing are designed to provide special protection against electric shocks.
  • Page 7: Setting The Clock

    Setting the Clock The UA-767PC blood pressure monitor is equipped with a date and time function. To set the clock on the device, follow these steps: Press the clock button on the front of the device. The blinking digits reflect the year. If they are not currently set on the correct year, press the START button to advance to the correct year.
  • Page 8: Preparation For Measurements

    Preparation for Measurements 1. Installing / Changing the Batteries Remove the battery cover and insert new batteries into the battery compartment as shown, taking care to observe the proper direction for each battery. Use R6P, LR6, AA or similar type batteries. CAUTION Insert the batteries as shown in the battery compartment.
  • Page 9: Selecting The Correct Cuff Size

    CUF-D-LA 22 cm to 32 cm Adult cuff CUF-D-A Arm size: The circumference of the biceps. Note: Model UA-767PC is not designed for using a small adult cuff. Symbols that are printed on the cuff Symbols Function/Meaning Recommended Action Set the...
  • Page 10: Applying The Arm Cuff

    Preparation for Measurements 5. Applying the Arm Cuff Do not roll up shirtsleeve tightly 1. Wrap the cuff around the upper arm, about 1-2 cm above the inside of the Cuff elbow, as shown. 1 to 2 cm Place the cuff directly against the skin, as clothing may cause a faint pulse, and result in a measurement error.
  • Page 11: Measurements

    Measurements 1. Place the cuff on the arm (preferably the left arm). 2. Set the PRESSURE switch to a value that will be 30 to 40 mmHg above the expected systolic value and press the START button. When the START button is pressed, all of the display symbols will appear for about one second.
  • Page 12 Measurements Remain still while the device is in operation. When a measurement is made with insufficient pressure, the device will pump again to a higher pressure. 4. When measurement has been completed, the buzzer sounds and the air is automatically released from the cuff. The systolic pressure, diastolic pressure readings, and the pulse rate are displayed.
  • Page 13: Notes For Proper Measurements

    Measurements Accurate measurement cannot be made if the exhaust velocity is outside the range of 2 to 5 mmHg. This can be determined by watching the display each time the "Measurement in Progress" symbol blinks. Note the reading as the "Measurement in Progress" symbol blinks. Notes for Proper Measurements Sit in a comfortable position where you can place the arm to be used for the measurement on a table or other support that will place the center of the upper...
  • Page 14: Data In Memory

    Data in Memory Storing the Data in Memory This device can automatically store up to 280 sets of measurement data in its memory. If an error message appears, the measurement data will not be stored. Whether the data will be stored or not after the measurement can be selected as follows: When the START button is pressed or the automatic power OFF function works after a measurement, the measurement data will be stored in memory.
  • Page 15: Transmitting Readings To A Computer

    “-“ appears one after another in succession and permission will be given to perform various functions. Measurement data of the UA-767PC can be monitored with “Monitor Pro” Data Analysis Software (UA-767P-13) and Printer terminal (TM-2480 series). For details, refer to the instruction manuals.
  • Page 16: About Blood Pressure

    About Blood Pressure What is Blood Pressure? Blood pressure is the force exerted by blood against the walls of the arteries. Systolic pressure occurs when the heart contracts. Diastolic pressure occurs when the heart expands. Blood pressure is measured in millimeters of mercury (mmHg). One's natural blood pressure is represented by the fundamental pressure, which is measured first thing in the morning while one is still at rest and before eating.
  • Page 17: Troubleshooting

    Regular readings give a more comprehensive blood pressure history. Be sure to note date and time when recording your blood pressure. Consult your doctor to interpret your blood pressure data. Troubleshooting Problem Possible Reason Recommended Action Nothing appears Batteries are drained. Replace all batteries with new ones.
  • Page 18: Maintenance

    2 years, to ensure proper functioning and accuracy. Please contact either your authorized dealer or A&D for maintenance. Technical Data Type UA-767PC Measurement method Oscillometric measurement Measurement range Pressure: 20 - 280 mmHg...
  • Page 19 Applied part Cuff Type BF Useful life Device: 5 years (when used six times a day) Cuff: 2 years (when used six times a day) Accessory AC adapter The adapter is to connect the blood pressure monitor to a power source at home. TB-233 Please contact your local A&D dealer for purchasing.
  • Page 20 1-243 Asahi, Kitamoto-shi, Saitama 364-8585 JAPAN Telephone: [81] (48) 593-1111 Fax: [81] (48) 593-1119 A&D INSTRUMENTS LIMITED Unit 24/26 Blacklands Way, Abingdon Business Park, Abingdon, Oxfordshire OX14 1DY United Kingdom Telephone: [44] (1235) 550420 Fax: [44] (1235) 550485 A&D ENGINEERING, INC. 1756 Automation Parkway, San Jose, California 95131 U.S.A.