2-12. HIGH TEMPERATURE
LIMIT CONTROL
(Continued)
405
Be sure capillary bulb of high limit is located behind
capillary bulb of thermostat. Both capillary bulbs
and bulb holders should be positioned as not to interfere
with basket or when cleaning the frypot wall, or damage to
capillary tube could result.
13. With excess capillary line pulled out, tighten smaller nut hand
tight, then ¼ turn with wrench.
14. Replace front panel.
15. Refill with shortening.