Setting Up The Controller; Setting The Clock; Setting The Schedule Timer; Description Of The Operation Modes - Daikin EDLQ036BA6VJU1 Operation Manual

Unit for air to water heat pump system
Hide thumbs Also See for EDLQ036BA6VJU1:
Table of Contents

Advertisement

Available languages

Available languages

Setting up the controller

After initial installation, the user can set the clock and day of the
week.
The controller is equipped with a schedule timer that enables the
user to schedule operations. Setting the clock and day of the week is
required to be able to use the schedule timer.

Setting the clock

1
Hold down the
pr
button for 5 seconds.
The clock read-out and the day of week indicator start flashing.
2
Use the
pi
and
pj
buttons to adjust the clock.
Each time the
pi
or
pj
increase/decrease by 1 minute. Keeping the
button pressed will increase/decrease the time by 10 minutes.
3
Use the
bi
or
bj
button to adjust the day of the week.
Each time the
bi
or
bj
previous day is displayed.
4
Press the
<
button to confirm the current set time and day of the
week.
To leave this procedure without saving, press the pr button.
If no button is pressed for 5 minutes the clock and day of the
week will return to their previous setting.
NOTE
The clock needs to be set manually. Adjust the setting
when switching from summertime to wintertime and
vice versa.

Setting the schedule timer

To set the schedule timer, refer to chapter "Programming and
consulting the schedule timer" on page 8.

Description of the operation modes

Space heating operation (
In this mode, heating will be activated as required by the water
temperature set point. The set point can be set manually (refer to
"Manual operation" on page 6) or weather dependent (refer to
"Selecting weather dependent set point operation (only in heating
mode)" on page 6).
Startup (
d
)
At the start of a heating operation, the pump is not started until a
certain refrigerant heat exchanger temperature is reached. This
guarantees correct startup of the heat pump. During startup, icon
d
is displayed.
Defrost (
d
)
In space heating operation or domestic water heating operation,
freezing of the outdoor heat exchanger may occur due to low outdoor
temperature. If this risk occurs, the system goes into defrost
operation. It reverses the cycle and takes heat from the indoor
system to prevent freezing of the outdoor system. After a maximum
of 8 minutes of defrost operation, the system returns to space
heating operation.
Operation manual
5
button is pressed, the time will
pi
or
pj
button is pressed the next or
)
h
Space cooling operation (
c
In this mode, cooling will be activated as required by the water
temperature set point.
The space cooling temperature set point can only
NOTE
be set manually (refer to "Manual operation" on
page 6).
Switching between space heating and space
cooling operation can only be done by pressing
the
=
button or by an external room thermostat.
Space cooling operation is not possible if the
installation is a "heating only" installation.
Domestic water heating operation (
In this mode, the indoor unit will heat up the domestic hot water tank
by heat pump when the space heating/space cooling operation has
reached its temperature set point or heat pump domestic water
heating has a higher demand request than space side (depends on
dipswitch setting). When necessary and when allowed by the booster
heater schedule timer (refer to "Programming quiet mode, booster
heating or domestic water heating" on page 9), the booster heater
provides auxiliary heating for the domestic hot water tank.
NOTE
In order to provide domestic hot water throughout
the day, it is advised to keep the domestic water
heating operation on continuously.
The domestic hot water temperature set point can
only be set manually (refer to "Manual operation"
on page 6).
Any
domestic
impossible when the domestic hot water tank is
not installed.
w
When the
delivered to the domestic hot water tank by the
solar kit option and not by the unit. Refer to
installation manual of the EKSOLHW solar kit.
Powerful domestic water heating operation
In the case of urgent need of domestic hot water, the domestic hot
water temperature set point can be reached quickly by using the
booster heater. Powerful domestic water heating operation is forcing
the booster heater to operate until the domestic hot water
temperature set point is reached.
This function remains available in solar operation.
Quiet mode operation (
)
s
Quiet mode operation means that the unit works at reduced capacity
so that the noise produced by the unit drops. This implies that the
indoor heating and cooling capacity will also drop. Beware of this
when a certain level of heating is required indoors.
Two quiet modes are available.

Disinfection function

When the w, ç, é and m icons are blinking together, the
disinfection function has been activated. This is not a malfunction.
Refer to "[2] Disinfection function" in the installation manual for more
details.

Freeze protection function

When the h, é and § icons are blinking together, the freeze
protection has been activated. This is not a malfunction. Refer to
"[4] Backup heater operation and space heating off temperature" in
the installation manual for more details.
EDLQ036~054BA6VJU1 + EBLQ036~054BA6VJU1
)
)
w
water
heating
operation
icon is blinking, hot water is
Unit for air to water heat pump system
4PW56183-1
is

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents