R
5
Venting Systems
A. Direct Connect Without Outside Air
Figure 15.1
NOTE:
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design
preference.
Fire Risk.
Inspection of Chimney:
• Masonry chimney must be in good condition.
• Meets minimum standard of NFPA 211
• Factory-built chimney must be 6 inch (152mm)
UL103 HT.
September 1, 2008
NOTE; Use metal plate
around exhaust vent pipe
and seal all edges with
non-flammable insulation
such as fiberglass, mineral
wool or ceramic material.
Do not use high tempera-
ture caulking materials to
seal any edge to prevent
future serviceability.
WARNING
Mt. Vernon Pellet Insert (AE)
B. Direct Connect With Outside Air
Figure 15.2
Never draw outside combustion air from:
Wall, floor or ceiling cavity
Enclosed space such as an attic or garage
NOTE:
In Canada, where passage through a wall or partition of
combustible construction is desired, the installation shall
conform to CAN/CSA-B365.
7036-135E
Outside Air
through
Rear Wall
CAUTION
Page 15