Venting Systems

A. Full Reline With Outside Air - Horizontal
CAUTION
Never draw outside combustion air from:
Wall, fl oor or ceiling cavity
Enclosed space such as an attic or garage
Figure 17.1
NOTE: In Canada, where passage through a wall or partition of
combustible construction is desired, the installation shall conform
to CAN/CSA-B365.
July 7, 2015
NOTE; Use metal plate around
exhaust vent pipe and seal all
edges with non-flammable insu-
lation such as , mineral wool or
ceramic.
Do not use high temperature
caulking materials to seal any
edge to prevent future service-
ability.
Fire Risk.
Inspection of Chimney:
• Masonry chimney must be in good condition.
• Meets minimum standard of NFPA 211
• Factory-built chimney must be a minimum 6 inch
(152mm) UL103 HT.
Outside Air through Rear
Wall (Horizontal)
NOTE:
Illustrations refl ect typical installations and are FOR DESIGN
PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design
preference.
7022-514C
CASTILE INSERT
WARNING
17