Siemens Advance Network Gateway User Manual page 12

Gateway with ethernet
Hide thumbs Also See for Advance Network Gateway:
Table of Contents

Advertisement

Specifications,
Continued
Housing, Explosion Protection,
Ratings and Certifications
Ambient Installation
Conditions
4
Advance Network Gateway
Wall Mounted Configuration
NEMA 3 (IP-54)
CSA Certified for Class I, Division 2, Group A,B,C,D
CENELEC non-Ex
(Air purge is not required for fire protection as indicated; however, the
unit may be air purged, if desired, for additional protection from envi-
ronmental elements.)
Rack Mounted Configuration
NEMA 2 (IP-20)
CSA Certified for Class I, Division 2, Group A,B,C,D
CENELEC non-Ex
Zone 1 Configurations
CENELEC approved EEx d IIC T6 Cortem CCA-04 enclosure
Electromagnetic and Radio Frequency Compatibility and Electrical
Safety
CE Compliance; certified to 89/336/ECC (EMC directive)
CE Compliance; certified to 73/23/EEC (Low Voltage directive)
Tested per EN 61010-1 / IEC 1010-1
Housing Materials and Colors
Stainless steel (1.4016); Front and top are commercial gray B
(RAL 7043), housing is light gray (RAL 7035)
Weight
Rack/Wall:
15 kg (35 pounds) approximately
Zone 1:
33 kg (73 pounds)
Operation: -18° to +50°C (0° to 122°F)
0-99% relative humidity (non-condensing) maximum
0-75% relative humidity year-round average
(Purge with dry air or nitrogen if required in tropical conditions.)
Must not be exposed to direct sunlight.
Must be protected from rain.
Storage and Transport: -25° to +65°C
2000590-001