Install Outside Air Kit; Junction Box Installation - Heat & Glo EM-415 - 36" Owner's Manual

Circulating wood burning fireplace installation and operation
Hide thumbs Also See for EM-415 - 36":
Table of Contents

Advertisement

E. Install Outside Air Kit
Keep duct runs short and straight to minimize restriction. A small dip is acceptable for a cold air trap.
The outside air kit must be installed on the left hand side of the fi replace.
Locate the air inlet in a clear area, preferably into prevailing wind during the heating season. Refer to Figure 5.2.
Install as shown in Figures 7.3, 7.4 and 7.5.
The air duct may be run vertically.
The outside air inlet must be at least 3 ft (.91 m) below the top of the uppermost chimney section.
CAUTION! Risk of Fire or Asphyxiation! DO NOT draw outside combustion air from wall, fl oor or ceiling cavity, or
enclosed spaces such as an attic or garage.
• DO NOT place outside air inlet close to exhaust vents or chimneys. Fumes or odor could be drawn into the room
through the fi replace.
• Locate outside air inlet to prevent blockage from leaves, snow/ice, or other debris. Blockages could cause combus-
tion air starvation.
Outside Air
• Hearth & Home Technologies Inc recommends using
• Secure flex duct with metal tape, screws or wire ties.
Figure 7.5
F. Junction Box Installation
NOTICE: Junction box should be installed during initial setup to avoid major reconstruction.
Your appliance is supplied with a junction box kit. We recommend the junction box be installed and wired at this time to
avoid reconstruction.
The junction box kit is to be installed on the right side of the appliance; remove and discard the metal knockout.
Attach the junction box bracket to the junction box as shown in Figures 7.6 - 7.10.
Bring the electrical wires to the inside of the junction box and secure in place with the Romex connector.
Install the duplex receptacle in the junction box and attach the cover plate.
Prior to attaching the junction box to the appliance, the heat shield supplied with your appliance must be installed. Insert
the top fl ange of the heat shield through the electrical knockout hole from the inside (Figure 7.9).
Attach the junction box bracket to the side of the appliance. See Figure 7.10. Secure with the screws provided in the
fastener package.
Flexible Duct
(not supplied)
Hood
2 Wire Ties
UL181 Class 0 or Class I rigid or flexible ducting.
Outside Air Installation
Heat & Glo • EM-415, EM-485 • 33056 • Rev W • 10/08
Outside Air
Plate
Assembly
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Em-415hEm-485thEm-485t - 42"

Table of Contents