Shrouds

A. Radiation Shield
Some shrouds require a radiation shield. Use where
specifi ed.
B. Field Constructed Shrouds
WARNING! Risk of Fire! Shrouds must be constructed
as specifi ed. Improper construction may overheat chase
top.
Chase top shrouds may be fi eld constructed where
permitted by regional building codes.
NOTICE: Some regional codes require an agency-Listed
shroud. Consult your local building offi cials.
Hearth & Home Technologies Inc. supplies UL listed
shrouds. See your dealer for details.
Shrouds must be constructed of minimum 26 ga sheet
metal.
Different shroud designs have been tested for Hearth Technologies fi replace systems using the TR11 and TR11T termination
caps.
The shrouds must be constructed from a minimum .018 in. (26 ga) thick aluminized steel.
The wire mesh is optional but recommended and must be .018 in. thick minimum.
Open Top Shroud (TR342 & TR11/TR11T caps require radiation shield)
Min.
Top Dim.
3 in (76 mm)
minimum
Min. Opening
Width
Min.
Base Dim.
Figure 10.2 Open Top Shroud Dimensions
36
Min.
Top Dim.
Min. Opening
Width
Min.
Base Dim.
Heat & Glo • EM-415, EM-485 • 33056 • Rev W • 10/08
Ø 17 1/2 in. (444.5 mm) Round Hole to fit over cap
Length x Width to fit inside shroud
Figure 10.1 Radiation Shield
TS345
in
23 x 23
mm
584 x 584
in
20 x 20
mm
508 x 508
Min. Opening Width
in
17 x 17
mm
432 x 432
3 in. (76 mm) tall legs
TR342
TR342/344TV
Min. Base Dims.
28 x 28
26 x 26
711 x 711
660 x 660

Radiation Shield

Required
Min. Top Dims.
25 x 25
23 x 23
635 x 635
584 x 584
22 x 22
20 x 20
559 x 559
508 x 508