10
10
Shrouds
A. Radiation Shield
•
Some shrouds require a radiation shield. Use where
specifi ed.
B. Field Constructed Shrouds
WARNING! Risk of Fire! Shrouds must be constructed
as specifi ed. Improper construction may overheat chase
top.
•
Chase top shrouds may be fi eld constructed where
permitted by regional building codes.
NOTICE: Some regional codes require an agency-Listed
shroud. Consult your local building offi cials.
•
Hearth & Home Technologies Inc. supplies UL listed
shrouds. See your dealer for details.
•
Shrouds must be constructed of minimum 26 ga sheet
metal.
•
Different shroud designs have been tested for Hearth Technologies fi replace systems using the TR11 and TR11T termination
caps.
•
The shrouds must be constructed from a minimum .018 in. (26 ga) thick aluminized steel.
•
The wire mesh is optional but recommended and must be .018 in. thick minimum.
Open Top Shroud (TR342 & TR11/TR11T caps require radiation shield)
Min.
Top Dim.
3 in (76 mm)
minimum
Min. Opening
Width
Min.
Base Dim.
Figure 10.2 Open Top Shroud Dimensions
36
Min.
Top Dim.
Min. Opening
Width
Min.
Base Dim.
Heat & Glo • EM-415, EM-485 • 33056 • Rev W • 10/08
Ø 17 1/2 in. (444.5 mm) Round Hole to fit over cap
Length x Width to fit inside shroud
Figure 10.1 Radiation Shield
TS345
in
23 x 23
mm
584 x 584
in
20 x 20
mm
508 x 508
Min. Opening Width
in
17 x 17
mm
432 x 432
3 in. (76 mm) tall legs
TR342
TR342/344TV
Min. Base Dims.
28 x 28
26 x 26
711 x 711
660 x 660
Radiation Shield
Required
Min. Top Dims.
25 x 25
23 x 23
635 x 635
584 x 584
22 x 22
20 x 20
559 x 559
508 x 508