Mantel And Wall Projections - Heatilator Direct Vent Gas Appliance EDV3633 Owner's Manual

Direct vent gas appliance
Hide thumbs Also See for Direct Vent Gas Appliance EDV3633:
Table of Contents

Advertisement

D. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).
Mantels
Note: All
measurements
in inches.
9
8
7
6
13-1/4
5
12-1/2
4
11-3/4
3
11
10-1/4
9-1/2
8-3/4
Measured from top of fireplace opening (in inches)
Figure 5.3
Minimum Vertical and Maximum Horizontal
Dimensions
30 in. minimum
to ceiling
18
17
16
15
20
14
19-1/4
13
18-1/2
12
17-3/4
11
17
10
16-1/4
15-1/2
14-3/4
14
Heatilator • Eclipse • 4049-229 Rev F • 11/08
Mantel Legs or Wall Projections
Top of
Appliance
A 2 in. (51 mm) min.
from fireplace opening
to perpendicular wall
Figure 5.4
Mantel Leg or Wall Projections (Acceptable on both
sides of opening)
Drywall
A
Mantel Leg or
Perpendicular Wall
21