F. Junction Box Installation
If the box is being wired from the OUTSIDE of the appli-
ance:
•
Remove the cover plate located on the outer shell - right
side (see Figure 12.4).
•
Install the supplied Romex™ connector in the cover
plate.
•
Make all necessary wire connections and reattach the
cover plate to the outer shell.
If the box is being wired from the INSIDE of the appli-
ance:
•
Remove the screw attaching the junction box/receptacle
to the outer shell, rotate the junction box inward to
disengage it from the outer shell (see Figure 12.4).
•
Pull the electrical wires from outside the appliance through
this opening into the valve compartment. See Figure
12.4.
•
Feed the necessary length of wire through the
connector.
•
Make all necessary wire connections to the junction box/
receptacle and reassemble the junction box/receptacle
to the outer shell.
G. Wall Switch Installation for Fan (Optional)
If the box is being wired to a wall mounted switch for use
with a fan (See Figure 12.5):
•
The power supply for the appliance must be brought into
a switch box.
•
The power can then be supplied from the switch box
to the appliance using a minimum of 14-3 with ground
wire.
•
At the switch box connect the black (hot) wire and red
(switch leg) wire to the wall switch as shown.
•
At the appliance connect the black (hot), white (neutral)
and green (ground) wires to the junction box as
shown.
•
Add a 1/4 in. insulated female connector to the red
(switch leg) wire, route it through the knockout in the face
of the junction box, and connect to the top fan switch
connector (1/4 in. male) as shown.
Heatilator • Caliber CD Series • 4040-263 Rev N • 11/08
GRN wire
inside box
Figure 12.4 Junction Box Detail
Minimum 14-3 AWG
with Ground
Red
Junction Box
Red
Figure 12.5 Junction Box Wired to Wall Switch or BC10
Romex
Connector
14/2WG
Cover Plate
outside firebox
Copper
ground attached
to GRN screw with
GRN wire
NOTICE: DO NOT wire
110 VAC to wall switch.
Switch
Black
Black
White
White
Green
Green
Power
Switch Box
Supply
Wires
Knockout
53